Operation - NorthStar M36029L Installation, Operation And Maintenance Manual

Northstar gasoline stationary air compressor
Table of Contents

Advertisement

INITIAL START-UP
1.Pump is shipped with oil. Remove the oil cap and
check pump oil level. Add SAE 30 non-detergent
pump oil (NorthStar part #35605), if necessary. Hand
tighten breather cap.
2. Turn pressure relief knob to engine start position.
Engine
Start
3. The engine is shipped without oil. Refer to the
engine manual for oil capacity and viscosity
recommendations.
4. Refer to engine manual to start your engine.
5. Once the engine has started, move the pressure
relief knob to the engine run position.
CAUTION! Unusual noise or vibration indicates a
problem. Do not continue to operate until you identify
and correct the source of the problem.
CAUTION! Do not attach air tools to open end of
the hose until start-up is completed and the unit
checks out OK.
6. Run the unit for 30 minutes, with ball valve open,
to break in pump parts.
7. Close the ball valve to shut off air flow. The
compressor is now ready for use.
8. After 50 hours of operation change the
compressor oil.

Operation

Breather
WARNING!
cap
the tank.
NOTE: Reduce tank pressure below 10 psi, then
drain moisture from tank daily to avoid tank
corrosion. Drain moisture from tank by opening the
drain petcock located at the bottom of the tank.
COMPRESSOR LUBRICATION
inadequate lubricant. Use of compressor without
lubricant or inadequate lubricant voids all warranties.
Synthetic lubricants are recommended after 50 hour
break-in. Compressor life is greatly increased with
the use of synthetic lubricants. CAUTION! If you will
Engine
be using synthetic lubricant, all downstream piping
run
material and system components must be
compatible.
Alkyd, Fluorosilicone, Flourocarbon, Polysulfide, 2-Component
Urethane, Nylon, Delrin, Celcon, High Nitrile Rubber (Buna N.
NBR more than 36 Acrylonite), Polyurethane, Polyethylene,
Epichlorohydrin, Polyacrylate, Melamine, Polypropylene, Baked
Phenolics, Epoxy, Modified Alkyds
Neoprene, Natural Rubber, SBR Rubber, Acrylic Paint, Lacquer,
Varnish, Polystyrene, PVC, ABS, Polycarbonite, Cellulose
Acetate, Latex, EPR, Acrylics, Phenoxy, Polysulfones, Styrene
Acrylonitile (San), Butyl
that is premium quality, does not contain detergents, contains
only anti-rust, anti-oxidation, and anti-foam agents as additives,
has a flashpoint of 440F (227C) or higher, and has a auto-
ignition point of 650F (343C) or higher.
See the petroleum lubricant viscosity table below. The table is
intended as a general guide only. Heavy duty operating
conditions require heavier viscosities. Refer specific operating
conditions to NorthStar Product Support at 1-800-270-0810
Monday - Friday 7:00 AM-5:30 PM, Saturday 7:30 AM-11:30 AM
Central Standard Time.
Temperature around
Compressor
Below 40F (4C)
40F to 80F
(4C to 27C)
80F to 100F
(27C to 38C)
Pump Capacities.
Refer to the following table for crankcase capacity
Item #
45938
5
Never disconnect threaded joints with pressure in
CAUTION! Do not operate without lubricant or with
Synthetic Lubricants
Suitable
Viton, Teflon, Epoxy (Glass Filled), Oil Resistant
(  indicates trademark of DuPont Corporation)
Not Recommended
Alternate Lubricants. You may use petroleum-based lubricant
Crankcase capacity
82 oz
Viscosity Grade
ISO
SAE
60
20
100
30
150
40