Dometic RM2355 Installation And Operating Instructions Manual

Dometic RM2355 Installation And Operating Instructions Manual

Aes iii refrigerator for lp-gas and electric operation

Advertisement

REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION
RA/RM-1D
RA/RM-2D
FOR YOUR SAFETY
If you smell gas:
1. Open windows and door.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
!
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult
a qualified installer, service agency or the
gas supplier.
8251240-08
WARNING
INSTALLATION AND

OPERATING INSTRUCTIONS

AES III
RM2355
RM2455
RM2555
RM4605
RM4805
MO-M 0811

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM2355

  • Page 1: Operating Instructions

    RA/RM-2D AES III FOR YOUR SAFETY If you smell gas: 1. Open windows and door. RM2355 2. Don’t touch electrical switches. 3. Extinguish any open flame. 4. Immediately call your gas supplier. FOR YOUR SAFETY Do not store or use gasoline or other...
  • Page 3: Table Of Contents

    INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it. OPERATING INSTRUCTIONS _______________________ 4 The refrigerator is designed for installation in motorhomes and intended for storage of foods, frozen foods and making ice. It CONTROL paNeL .
  • Page 4: Operating Instructions

    STARTING THE REFRIGERATOR OPERATING INSTRUCTIONS WARNING CONTROL PANEL Whilst mobile: • Do not operate the refrigerator on LP gas . • Turn off the gas bottle . 1). The refrigerator starts in the Press the ON/OFF button ( mode it was in when it was turned off. 2) and LED (A) or (B) comes Press the AES/GAS button ( on.
  • Page 5: 230-240V Operation

    Burner failing to remain alight. In case the appliance fails to operate correctly, contact an au- Do NoT store explosive substances in the refrigerator, thorised Dometic Service Centre. such as cigarette lighter gas, gasoline, ether or the like . 230-240V OPERATION FOOD STORAGE Always keep food in closed containers.
  • Page 6: Defrosting

    DEFROSTING REPLACING THE bULb Frost will gradually accumulate on the refrigerating surfaces. To replace the bulb, follow these steps: Each time the door is opened some of the cold air in the refrig- Remove the lamp cover. erator spills out and is replaced by warm moist room air. As RM4605/RM4805: Push the lamp cover backwards.
  • Page 7: Product Care - Some Useful Hints

    The ventilation is inadequate owing to reduced area of the We recommend fitting the Dometic ventilation system, which ventilation passages (partial blockage of grilles from wire is specially developed by Dometic for this purpose. The mesh etc.). Dometic ventilation grilles permit inspection and small repairs •...
  • Page 8 RM4605/RM4805 The flue gases are dispersed from the ventilation passage using (Fig. 5 & Fig. 6) the Dometic flueing system. The top, bottom and sides of the (Fig. 5 & Fig. 7) ventilation passage should be insulated to prevent condensa- tion and cold draughts.
  • Page 9: Connecting Points

    CONNECTING POINTS Dimensions to connecting points (mm). RM2355 Electrical 166.1 connection connection point point Flue outlet pressure test point Electrical connection connection point point RM2455 Electrical connection connection point point 327.4 Flue outlet pressure test point connection point Electrical connection...
  • Page 10 RM2555 Electrical connection connection point point 327.4 Flue outlet pressure test point Electrical connection connection point point RM4605/RM4805 Electrical connection connection point 325.4 point Flue outlet pressure test point 12V DC Electrical connection connection point point...
  • Page 11: Securing The Refrigerator

    For this reason the re- • RM2355: The installer must block the space between the frigerator should be installed if possible not at the entrance side storage cabinet and the top of the refrigerator.
  • Page 12: Drain Water Hose

    Seal around the hose that Fig. 16 goes through the drilled RM2355 hole. Fig. 13 If a longer hose than Secure the refrigerator and the lower supplied is required to...
  • Page 13 12 volt. • Ignite the burner to ensure correct operation of gas valve, RM2355, RM2455 and RM2555: One terminal is marked burner and ignition. “Connect to permanent 12 Volt DC house battery” and the other “Connect to Vehicle 12 Volt DC battery”, see Fig. 19.
  • Page 14: Mounting Instructions

    This kit is 6 mm cross-section low voltage multi strand cable. delivered with RM2355 but must be bought separately for RM4605/RM4805 • RM2455 and RM2555 (part number 2932750-13/2) as well as Maximum length of 8 meters from refrigerator to the battery.
  • Page 15 POSITIONING OF SHELVES...
  • Page 16: Technical Data

    TECHNICAL DATA RM2355 RM2455 RM2555 RM4605 RM4805 overall dimensions height (mm) 1104 1385 1544 Width (mm) Depth incl. cooling unit (mm) Recess dimensions height (mm) 1083 1365 1522 Width (mm) Depth (mm) Capacity Gross (litres) Weight without packaging (kg) 44,5...
  • Page 17: Rearview Equipment

    REARVIEW EqUIPMENT RM2355 Heaters Flue baffle Reigniter Relay Drain water hose Power module cover (PC board) Protection cover Inlet fitting Screw for protection cover Burner jet Vehicle battery connection Manual gas shutoff valve Flexible cord 12V DC only House battery connection...
  • Page 18: Wiring Diagram

    WIRING DIAGRAM RM2355 RM2455/RM2555...
  • Page 19: Wiring Diagram

    WIRING DIAGRAM RM4605/RM4805 3 8 5 1 4 2 2 P 1 − 1 P 3 − 4 P 1 − 4 P 3 − 3 P 1 − 2 P 3 − 2 P 1 − 5 P 3 − 1 P 1 −...
  • Page 20: Gas Safety System

    WORkING INSTRUCTIONS FOR THE GAS SAFETY SYSTEM WORkING DIAGRAM Thermostat Spark Gas valve Flame detector device Lock out indication TW TS TS TWI TS TWI TS TECHNICAL SPECIFICATIONS Classification codes according to EN298 A-M-R-V-X-K Class of protection according to Low Voltage Directive IP-20 Waiting time / TW Safety time / TS...
  • Page 21: Appendix A - Airing Position Card

    APPENDIX A - AIRING POSITION CARD Use the Airing Position Card to keep the doors ajar if the refrigerator will not be in use for an extended period of time or put in storage. RM2455/RM2555...
  • Page 22 APPENDIX A - AIRING POSITION CARD RM4605/RM4805...

This manual is also suitable for:

Rm2555Rm4605Rm4805Rm 2455

Table of Contents