RA/RM-2D AES III FOR YOUR SAFETY If you smell gas: 1. Open windows and door. RM2355 2. Don’t touch electrical switches. 3. Extinguish any open flame. 4. Immediately call your gas supplier. FOR YOUR SAFETY Do not store or use gasoline or other...
INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it. OPERATING INSTRUCTIONS _______________________ 4 The refrigerator is designed for installation in motorhomes and intended for storage of foods, frozen foods and making ice. It CONTROL paNeL .
STARTING THE REFRIGERATOR OPERATING INSTRUCTIONS WARNING CONTROL PANEL Whilst mobile: • Do not operate the refrigerator on LP gas . • Turn off the gas bottle . 1). The refrigerator starts in the Press the ON/OFF button ( mode it was in when it was turned off. 2) and LED (A) or (B) comes Press the AES/GAS button ( on.
Burner failing to remain alight. In case the appliance fails to operate correctly, contact an au- Do NoT store explosive substances in the refrigerator, thorised Dometic Service Centre. such as cigarette lighter gas, gasoline, ether or the like . 230-240V OPERATION FOOD STORAGE Always keep food in closed containers.
DEFROSTING REPLACING THE bULb Frost will gradually accumulate on the refrigerating surfaces. To replace the bulb, follow these steps: Each time the door is opened some of the cold air in the refrig- Remove the lamp cover. erator spills out and is replaced by warm moist room air. As RM4605/RM4805: Push the lamp cover backwards.
The ventilation is inadequate owing to reduced area of the We recommend fitting the Dometic ventilation system, which ventilation passages (partial blockage of grilles from wire is specially developed by Dometic for this purpose. The mesh etc.). Dometic ventilation grilles permit inspection and small repairs •...
Page 8
RM4605/RM4805 The flue gases are dispersed from the ventilation passage using (Fig. 5 & Fig. 6) the Dometic flueing system. The top, bottom and sides of the (Fig. 5 & Fig. 7) ventilation passage should be insulated to prevent condensa- tion and cold draughts.
CONNECTING POINTS Dimensions to connecting points (mm). RM2355 Electrical 166.1 connection connection point point Flue outlet pressure test point Electrical connection connection point point RM2455 Electrical connection connection point point 327.4 Flue outlet pressure test point connection point Electrical connection...
Page 10
RM2555 Electrical connection connection point point 327.4 Flue outlet pressure test point Electrical connection connection point point RM4605/RM4805 Electrical connection connection point 325.4 point Flue outlet pressure test point 12V DC Electrical connection connection point point...
For this reason the re- • RM2355: The installer must block the space between the frigerator should be installed if possible not at the entrance side storage cabinet and the top of the refrigerator.
Seal around the hose that Fig. 16 goes through the drilled RM2355 hole. Fig. 13 If a longer hose than Secure the refrigerator and the lower supplied is required to...
Page 13
12 volt. • Ignite the burner to ensure correct operation of gas valve, RM2355, RM2455 and RM2555: One terminal is marked burner and ignition. “Connect to permanent 12 Volt DC house battery” and the other “Connect to Vehicle 12 Volt DC battery”, see Fig. 19.
This kit is 6 mm cross-section low voltage multi strand cable. delivered with RM2355 but must be bought separately for RM4605/RM4805 • RM2455 and RM2555 (part number 2932750-13/2) as well as Maximum length of 8 meters from refrigerator to the battery.
WORkING INSTRUCTIONS FOR THE GAS SAFETY SYSTEM WORkING DIAGRAM Thermostat Spark Gas valve Flame detector device Lock out indication TW TS TS TWI TS TWI TS TECHNICAL SPECIFICATIONS Classification codes according to EN298 A-M-R-V-X-K Class of protection according to Low Voltage Directive IP-20 Waiting time / TW Safety time / TS...
APPENDIX A - AIRING POSITION CARD Use the Airing Position Card to keep the doors ajar if the refrigerator will not be in use for an extended period of time or put in storage. RM2455/RM2555...
Page 22
APPENDIX A - AIRING POSITION CARD RM4605/RM4805...