Table Of Contents; Minimum Clearances To Combustibles - WLee OUTDOOR FIREPIT FOR PROPANE AND NATURAL GAS Owner's Manual

Outdoor firepit for propane and natural gas
Table of Contents

Advertisement

O.W. LEE OUTDOOR CAMPFIRE -
Cover - Important Safety Information...................................................................................... 1
Table of Contents................................................................................................................ 2
Minimum Clearances to Combustibles........................................................................ 2
Pre-Installation & Preparation Guidelines..................................................................... 3
Connecting the Gas to the Campfire............................................................................. 4
Lava Granules and Logs Parts List............................................................................... 4
Lava Granule & Log Placement..............................................................................................5
Operating Instructions...........................................................................................................6
Lighting Instructions................................................................................................. 6
Operating Information............................................................................................... 7
Converting your Campfire to a Different Gas Type...........................................................8
READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR CAMPFIRE.
If not installed and used correctly per these instructions, this product can cause serious injury.
CAUTION: INSTALLATION, MODIFICATION AND REPAIR MUST BE DONE BY
Be sure you understand all safety precautions and warnings contained in this manual.
A. CHECK STATE AND LOCAL CODES TO DETERMINE IF THE OUTDOOR CAMPFIRE IS
PERMITTED IN YOUR LOCALITY BEFORE INSTALLATION.
B. FOR OUTDOOR USE ONLY. THIS UNIT MUST BE INSTALLED AT LEAST 60" FROM
CENTER OF BURNER TO ANY COMBUSTIBLE WALLS OR MATERIAL.
IT MUST NOT BE INSTALLED UNDER ANY TYPE OF CEILING OR OVERHANG.
C. When shutting the unit down-be sure to TURN THE CONTROL VALVE FULLY OFF.
D. WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH. DO NOT
MODIFY THIS OUTDOOR CAMPFIRE OR ITS CONTROLS, EXCEPT AS PROVIDED
FOR IN THIS MANUAL.
Any other change may be dangerous. Improper installation or use of your outdoor
campfire can cause serious injury or death from fire, burns, explosions or carbon monoxide
poisoning.
NOTHING SHOULD BE ABOVE THE OUTDOOR CAMPFIRE
60"
CLEARANCE
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION
IMPORTANT SAFETY INFORMATION
A QUALIFIED, PROFESSIONAL INSTALLER.
MINIMUM CLEARANCE TO COMBUSTIBLES
NOTE
CLEARANCE
FROM CENTER
TO ANY
COMBUSTIBLE
CONSTRUCTION

TABLE OF CONTENTS

Clearances to Combustible Construction:
Sidewalls: 60" from center of unit (Figure 1)
Ceiling: Nothing should be above the outdoor
60"
campfire
Flooring: 0" - Can be installed on deck, slab,
floor, etc.
The dimensions shown in Figure 1 are MINIMUM
CLEARANCES to maintain when you install this
outdoor campfire. THERE MUST BE AT LEAST
60" of clearance from the center of the unit to
any combustible sidewalls. The unit MUST NOT
BE installed under any type of ceiling or overhang.