Humminbird Legend 3000 Operation Manual
Humminbird Legend 3000 Operation Manual

Humminbird Legend 3000 Operation Manual

Legend 3000 series

Advertisement

Operations Manual
Operational instructions for Humminbird Legend 3000 Series
including the Legend –3000, 3005, 3000 Deep and 3005 Deep

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Legend 3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Humminbird Legend 3000

  • Page 1 Operations Manual Operational instructions for Humminbird Legend 3000 Series including the Legend –3000, 3005, 3000 Deep and 3005 Deep...
  • Page 2: Thank You

    We encourage you to read this operation manual carefully in order to get full benefit from all the features and applications of your Humminbird product. Contact our Customer Resource Center at either 334-687-0503 or www.humminbird.com.
  • Page 3: Table Of Contents

    Customer Support ........15 Section 3: SPECIFICATIONS Legend 3000/3005 Specifications ......16 Legend 3000...
  • Page 4: Section 1: Using The Legend 3000 Series

    2' EGEND ERIES to 600' (2000' for the Legend 3000 Deep and 3005 Deep Models). Actual depth capability depends on many factors such as bottom hardness, water conditions, and transducer installation. All sonar units typically read to deeper depths in fresh water than in salt water.
  • Page 5: User Interface

    EGEND list, then ONTROL ANEL knob to adjust ANGE list from the display by ANGE USING THE LEGEND 3000 SERIES USER INTERFACE / KNOBS / LCD DISPLAY uses a high- ERIES 3000 EGEND UTOMATIC 3000 S selects the depth range. In M...
  • Page 6: Chart Window

    USING THE LEGEND 3000 SERIES REAL TIME SONAR™ / CHART WINDOW The sonar returns received by the displayed along the depth range scale in a ™ (RTS) W ONAR INDOW HART INDOW displays new sonar information within the transducer cone in an expanded, easy-to-see format; the...
  • Page 7 200kHz sonar information and the target information from the 50kHz sonar. See for details on selecting the sonar views. HART PANELS setting and PEED USING THE LEGEND 3000 SERIES Bait fish Fish Arch Partial Fish Arch Structure HART...
  • Page 8: Control Panels

    The first Control Panel to set is Mode. Three modes of operation control the method used by the Legend 3000 Series to track the bottom, select depth ranges and graph the information on the LCD display. The Mode is selected by changing the Control Panel setting to Auto, Manual, or BTM Lock (Bottom Lock).
  • Page 9: Automatic Mode

    Optimizing the Depth Range for Sonar Targets When the image of the bottom does not appear close to the bottom of the LCD display, the Legend 3000 Series is not fully optimizing the display to...
  • Page 10: Bottom Lock Zoom Mode

    To adjust the depth ranges Adjustment Indicator manually, follow these steps: 1. Make sure the Legend 3000 Series is operating in Manual mode. 2. Push the Range knob. An is operating in...
  • Page 11: Chart Speed

    The Light setting defaults to factory settings after the Legend 3000 Series is turned off. The factory setting full at power up and automatic decrease to HART INDOW...
  • Page 12: Surface Clutter

    USING THE LEGEND 3000 SERIES SURFACE CLUTTER / WHITE LINE / FILTER / DEPTH ALARM / TEMP ALARM Surface Clutter eliminates URFACE LUTTER most sonar returns near the water surface caused by trapped air, boat wakes and temperature inversions. Most surface clutter appears on the display because the strongest sonar returns come from the shallowest objects.
  • Page 13: Temp Alarm

    The outside temp alarm will sound when the water temperature was initially above the temp boundary and then falls below it. OWER Legend 3000 Series is turned off. The factory setting ° F/ 22° C. Fish Alarm (Deep Models only) LARM...
  • Page 14: Simulator

    Simulator Mode if a transducer is connected. When operating with the Simulator on and without a transducer connected, the Legend 3000 Series does not remember any changes to settings. The Simulator setting defaults to factory settings after the Legend 3000 Series is turned off.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Repairs Do not attempt to repair the EGEND There are no user-serviceable parts inside, and special tools and techniques are required for reassembly to ensure the waterproof integrity of the housing. Repairs should be performed only by authorized Techsonic technicians. Before You Call Customer Support Many requests for repair received by Techsonic involve units that do not actually need repair.
  • Page 16: Warranty

    MAINTENANCE AND WARRANTY TROUBLESHOOTING / WARRANTY / SERVICE POLICY 5. The unit comes on before I press POWER, and won’t turn off. Check the transducer cable—if the outer jacket of the cable has been cut and the cable is in contact with bare metal, you need to disconnect the cable from the unit, then repair the cut with electrical tape.
  • Page 17: Customer Resource Center

    We reserve the right to deem any product unserviceable when replacement parts are no longer available or impossible to obtain. This Service Policy is valid in the United States only. This applies only to Humminbird products returned to our factory in Eufaula, Alabama. This Service Policy is subject to change without notice.
  • Page 18: Section 3: Specifications Legend 3000/3005 Specifications

    SPECIFICATIONS 3000/3005 SPECIFICATIONS Operating Frequency ....... 200 kHz Power Output ..... . .4000 Watts (Peak to Peak) .

This manual is also suitable for:

Legend 3000 deepLegend 3005Legend 3005 deep

Table of Contents