Monitor Mode
To enter Monitor Mode, connect the terminal cable, start your terminal program, and hold the Button down while
powering on the Eggtimer. You will see a "MON>" prompt on your terminal screen. Hit the one-character monitor
code to perform the function, some of them also require that you press the Button to start them;
Monitor Codes:
0 - Dump LAST USED memory page to data port in .CSV format
A - Dump ALL memory pages to data port in .CSV format (this takes awhile...)
M - Fire Main (CHA) channel for programmed number of seconds
(you need to press the Button to fire the channel)
B - Fire CHB channel for programmed number of seconds
(you need to press the Button to fire the channel)
S - SET the servo channels selected in the programming screen (programmed direction)
R - RESET the servo channels selected in the programming screen (opposite direction)
1 - Fire AUX1 output for 2 seconds (you need to press the Button to fire)
2 - Fire AUX2 output for 2 seconds (you need to press the Button to fire)
3 - Fire AUX3 output for 2 seconds (you need to press the Button to fire)
Programming Screen (Example)
Eggtimer Build_1.48b
A
200
LDA <50-500 by 50>
B
20
Ascent Samp/sec: <4,5,8,10,15,20,25,33>
50
Interval (ms)
C
1
Descent Samples/sec <1,2,4,5,10>
1000
Interval (ms)
D
1
Main Enable <0-Off, 1-IGN, 2-Servo CCW, 3-Servo CW>
E
500
Main Altitude <100-2000 by 50, 0 @ Apogee>
F
2
Main ON-Time <1-9, 0-Cont.>
G
1
CHB Enable <0-Off, 1-IGN, 2-Servo CCW, 3-Servo CW,
H
2
CHB ON-Time <1-9,0-Cont.>
I
2000
Burn Timer <100-20000 ms by 100>
J
0
Airstart Delay <0-9900 ms by 100>
K
0
Airstart Min Velocity <0-700 by 50>
L
0

Telemetry

O
Comments:
Options: Esc, A-O, ?
• To update the real-time readings on the right-hand side, press the ENTER key
• To change values: press the LETTER of the option, use +/- to change the values, hit ENTER to accept value
• To accept settings and save, hit the ESC key... you will hear a long beep and the LEDs will remain flashing
(Eggtimer is now in Halted mode)
• To perform a Master Reset, clearing all flight memory and resetting to initial settings, hit CTRL and Y, then hold
button for 10 seconds to confirm (You should only need to do this once, unless otherwise instructed)
Flight Display
• To enter Flight Display mode, press the ? key from the Programming Screen:
Eggtimer Build-1.48b
Page
Apogee
A
18
1347
B
17
1235
C
16
0
D
15
1346
E
14
0
F
13
0
G
12
1170
H
11
0
I
10
642
J
9
939
K
8
1509
Flight Settings
4-Airstart, 5-Airstart w/o Breakwire>
Typical Multiple Deployment
Saved Flight Summary
Max V
Comments
565
flight 2013-04-28a f24 dd
420
F30 Flight 3
0
F30 Flight 3
416
F30 Flight 2
0
F30 Flight 2
0
Test F30
387
Default Flight6
0
Test
239
Vagabond E12
412
Vagabond E28
487
Vagabond F39 #2
T:23.50
P:97804.00
A:975.39
Main:0
CHB:0
Batt:3.12
- 55 -