Diode Test; Specifications - Velleman AVM360 Operation Manual

Analog multimeter
Hide thumbs Also See for AVM360:
Table of Contents

Advertisement

4.8 Diode test

1. Set the range selector at selected range position :
x 1K for 0 - 150 µA test,
x 100 for 0 - 1.5 mA test,
x 10 for 0 - 15 mA test,
x 1 for 0 - 150 mA test.
2. Connect the diode to the tester.
For I
(forward current) test, connect the "N" terminal of the tester to the
F
positive polarity of the diode and the "P" terminal to the negative polarity of the
diode. For I
(reverse current) test, reverse the connection.
R
3. Read I
or I
one the LI scale provided.
F
R
4. Read the linear (forward) voltage of the diode on the LV scale while testing I
or I
.
R

5. Specifications

5.1 DC Voltage
Ranges : 0.1 - 0.5 - 2.5 - 10 - 50 - 250 - 1000 V
Accuracy at FSD : 3
Sensitivity : 20 kΩ / V
Extension : 25 kV (with HV probe extra)
5.2 AC Voltage
Ranges : 10 - 50 - 250 - 1000 V
Accuracy at FSD : 4
Sensitivity : 9 kΩ / V
Decibelmeter : -10 to +22 dB
0 dB = 1mW / 600 Ω
5.3 DC Current
Ranges : 50 µA (at 0.1 VDC position) - 2.5 mA - 25 mA - 0.25 A
Accuracy at FSD : 3
Volt Drop : 250 mV