Ep Lock Shaft - Oki 18 Service Manual

Oki data printer
Table of Contents

Advertisement

Page: 51
Service Guide OKIPAGE 18/18n
Chapter 3 Parts Replacement

3.3.22 EP lock shaft

(1) Turn the AC power switch off. Unplug the AC power cord from the outlet.
(2) Remove Frame-Main [See 3.3.12 (7)].
(2)
(3) Remove screw (1). Turn EP lock lever (L) Assy
in the direction of arrow (A) .
(3)
(4) Remove spring
.
(4)
(5) Drop EP lock shaft
down and turn in the direction of arrows (B) and remove it.
Copyright 1998, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner
Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)