H1
Example
H2 = 2ft
2 - (90° + 90°) = 6ft
V1 = 21ft
H = 8ft
Page 28

EXAMpLES - TOp vENT RUN

24"
24" MINIMUM
CLEARANCE TO
COMBUSTIBLES
H2
V1
V = 15ft
Figure 29
H2
H1
Example
H2 3ft, H3 1ft = 4ft
(90° + 90° + 90°) = 6ft
V1 = 21ft
H = 10ft
V = 21ft
Figure 30
H1
Example
H1 = 2ft
V1 = 20ft
H = 2ft
V = 20ft
Figure 31
H3
V1
V1