AWS KG-10 Instruction Manual

AWS KG-10 Instruction Manual

Kg-series high capacity precision balance
Hide thumbs Also See for KG-10:

Advertisement

KG-Series
American
Weigh
High Capacity
Scales, Inc.
Precision Balance
INSTRUCTION
MANUAL
KG-10
KG-20
©2010 American Weigh Scales, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KG-10 and is the answer not in the manual?

Questions and answers

Summary of Contents for AWS KG-10

  • Page 1 KG-Series American Weigh High Capacity Scales, Inc. Precision Balance INSTRUCTION MANUAL KG-10 KG-20 ©2010 American Weigh Scales, Inc.
  • Page 2: Table Of Contents

    KG-Series Manual TABLE OF CONTENTS INTRODUCTION KG-Series Balance Structure ..............p. 3 Technical Specifications .
  • Page 3: Kg-Series Balance Structure

    KG-Series Manual 1.1. KG-Series Balance Structure Figure 1.3 Weighing Pan UNIT Button Leveling Foot Weight Display TARE Button Battery Compartment Bubble Level MODE Button ON/OFF Button CAL Button...
  • Page 4: Technical Specifications

    KG-Series Manual 1.2. Technical Specifications Model KG-10 KG-20 Max. Capacity 10,000g 20,000g Readability 0.1g 0.1g Repeatability ±1d Linearity ±2d Span Calibration Weight 5000g 10,000g Linear Calibration 5000g, 10000g 10,000g, 20,000g Weights Response Time 2~3 sec. Pan Size 12 x 9 inch Dimensions 12 x 12.5 x 7 inch...
  • Page 5: Installation

    KG-Series Manual 2. INSTALLATION 2.1. Part List Balance ............1 pc. Weighing Pan .
  • Page 6: Operation

    KG-Series Manual 3. OPERATION 3.1. Sample Weighing 1. Press TARE / ZERO to make the balance return to zero. 2. Load the sample onto the scale pan. 3. The weight is stable when g (depending on weighing unit is active) appears on the display. NOTE: For accurate weight results, it is important to load the sample to be weighed, onto the center of the platform.
  • Page 7: Linear Calibration

    KG-Series Manual • If ambient temperatures have changed greatly 1. Prepare the calibration weight (see pg. 4 for required calibration weights). 2. Clean the weighing pan and press TARE to re-zero the balance. 3. When the balance is stablized, press and hold the CAL button for 5 seconds. 4.
  • Page 8: Appendix

    KG-Series Manual 4. APPENDIX 4.1. RS232 Serial Data Communication This balance has a Bi-Directional RS232 port for communication with a PC. When connected to a computer, the weight value can be sent to the computer and commands can be sent to the balance Transfer Format: Asynchronous Communication Protocol: 1 start bit, 8 data bits, 1 stop bit Baud Rate: 9600...
  • Page 9: Troubleshooting

    KG-Series Manual 4.4. Care & Maintenance Please read all operating instructions carefully before use. Scales are precision instruments and should always be handled with proper care. To ensure years of reliable service, keep these simple tips in mind: • Do not exceed the scales maximum capacity. Overloading your scale can permanently damage it! • Avoid exposure to extreme heat or cold. Scales perform best at normal room temperature. If temperatures have changed dramatically, recalibration may be necessary.