EcoSmart Fire BK5 Installation, Operation And Maintenance Manual

EcoSmart Fire BK5 Installation, Operation And Maintenance Manual

Bk series; xl series; ab series; xs series

Advertisement

INSTALLATION, OPERATION
AND MAINTENANCE MANUAL
Please read these instructions completely
before operating the EcoSmart™ Fire.
Burner Range
BK Series
XL Series
AB Series
XS Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BK5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EcoSmart Fire BK5

  • Page 1 INSTALLATION, OPERATION AND MAINTENANCE MANUAL Please read these instructions completely before operating the EcoSmart™ Fire. Burner Range BK Series XL Series AB Series XS Series...
  • Page 2 ENGLISH Bioethanol fireplaces are classified by regulations and standards as decorative fireplace appliances intended for occasional use only (not for heating). Refer to Material Safety Data Sheet (MSDS) of the brand of fuel used for important Health and Safety information. Register your warranty online at www.ecosmartfire.com www.ecosmartfire.com...
  • Page 3: Table Of Contents

    Regulating the flame Baffles Turning your Burner OFF - Extinguishing the flame Re-igniting the Burner Caring for your EcoSmart Fire Troubleshooting Your Warranty After Sales Service © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 4: Important Safety Information

    1. EXPLOSION/FIRE HAZARD dangerous goods. iv. The Fire Company Pty Ltd is not liable for any damage caused by using the incorrect type of fuel. WARNING i. Use only approved Bioethanol fuel. Never use gasoline.
  • Page 5 If you have any questions regarding any of the above important safety information please contact your distributor or The Fire Company Pty Ltd. Please store these warnings in a safe place for future reference. © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 6: Standard Equipment Received

    Series Model Top Tray Manual Jerry Can Lighting Rod Lighter BK Series BK5, BK3, BK2UL XL Series XL900, XL700, XL500 XS Series XS340 AB Series AB8, AB3 Burner The Burner is the core product of the EcoSmart™ Fire as it is the chamber that houses the fuel.
  • Page 7 Lighter image is indicative only, the model included may vary from time to time. h 185mm x w 15mm x d 15mm h [7.3in] x w [0.6in] x d [0.6in] © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 8 ENGLISH Standard Equipment Received Wind Screen Static For those models that come with a Wind Screen Static - the Wind Screen can be fixed to the front of the model via the four (4) fixing points on the firebox facade using the circular screws provided. If a wind screen is not required, the model includes four (4) stainless steel plugs to hide these fixing points.
  • Page 9: Markings

    • A fire extinguisher is strongly recommended For occasional decorative use. Not for heating. Register your warranty at www.ecosmartfire.com Remove label before use. BK3 & BK2UL © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 10: Clearances & Installation

    Fireboxes. The Fire Company Pty Ltd recommends using the Burner in a firebox manufactured by The Fire Company Pty Ltd only. The Fire Company Pty Ltd is not liable for any injuries or damages sustained through the use of custom made or privately commissioned Fireboxes. As noted in warning 2ii, a fire extinguisher is strongly recommended.
  • Page 11 - Fitted within a Top Tray which is not more than 200% the size of the total Burner size. © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 12 The size of the cut-out should not give more than 5mm [0.196in] clearance. Top Trays must not be more than 200% of the total size of the If utilising a Top Tray that is not supplied, The Fire Company Pty corresponding Burner.
  • Page 13: Clearances & Installation

    Ø335mm min depth 115mm Cut Out 80mm min depth Cut Out [3.9in] [18.9in] [6.3in] 100mm [12.4in] 160mm 480mm [6.5in] 315mm [6.3in] 165mm 160mm XL500 XS340 © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 14: Ventilation & Efficiency

    ENGLISH Ventilation & Efficiency Ventilation EcoSmart™ Fires do not require any form of permanent fixture or fitting, such as a flue for ventilation, a permanent connection or any kind of fixed utility for fuel supply. Bioethanol is safe to burn indoors without venting, because its main by-products are carbon dioxide, water steam and heat.
  • Page 15: Ventilation & Efficiency

    Using e-nrg is a compulsory requirement in some countries - check with your local distributor. Thermal Efficiency All EcoSmart™ Fire Burners have a Thermal Efficiency of over 90%. © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 16: How To Operate The Burner

    ENGLISH How to operate the Burner Follow these instructions to operate your Burner safely. Decanting your Bioethanol into the jerry can WARNING: Bioethanol is a flammable liquid. Store only in original Decanting must be performed in a well-ventilated area to ensure that container or jerry can.
  • Page 17: Decanting The Fuel From The Jerry Can Into The Burner

    MAX line. AB8 & AB3: To fill the AB Series, position the jerry can spout in the middle of the burner mouth. © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 18: Lighting The Burner

    ENGLISH How to operate the Burner Lighting the Burner Regulating the flame Keep hands and face the length of the lighting rod away from Wait until the fire is established (approx 10 minutes) before regulating. the Burner at all times, particularly when igniting. Before lighting, ensure that the Burner is clear and ready for use.
  • Page 19: Turning Your Burner Off - Extinguishing The Flame

    A pressurised ignition can cause serious burns if you are close to the Burner. 3. Re-ignite as described in “Lighting the Burner”. © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 20: Caring For Your Ecosmart Fire

    ENGLISH Caring for your EcoSmart™ Fire Maintenance and cleaning must only be performed when the Cleaning the Firebox Burner is OFF, COMPLETELY EMPTY & DRY and at ROOM As the stainless steel is exposed to flame and heat for a long period of TEMPERATURE.
  • Page 21: Troubleshooting

    Clean/service the Burner and see if you find the obstruction. If you do not find anything, contact your distributor. Do not use again until it has been serviced. © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V8 090911...
  • Page 22: Your Warranty

    For warranty claims please contact your local distributor. If there is not a local distributor in your country please visit www.ecosmartfire.com to source the details of the country closest to you. *Do not return this form to The Fire Company Pty Ltd, please retain for your own reference. www.ecosmartfire.com...
  • Page 23: After Sales Service

    Reproduction of this manual in any manner, in any language, in whole or in part without prior written permission is prohibited. The Fire Company Pty Ltd reserves the right to correct any errors or misprints. We also reserve the right to alter information without notification. The information provided herein is believed to be correct but is not guaranteed.
  • Page 24 T: +61 2 9997 3050 E: info@thefirecompany.com.au REV090911...

This manual is also suitable for:

Bk3Xl900Bk2ulXl700Xl500Xs340 ... Show all

Table of Contents