OILLESS AIR COMPRESSOR
COMPRESSOR DISCHARGE AIR MAY CONTAIN HYDROCARBONS AND OTHER
CONTAMINANTS! DO NOT USE DISCHARGE AIR FOR BREATHING!
Genuine ROLAIR replacement parts are sold nationwide through a network of authorized dealers and service
centers. Please contact the dealership where your air compressor was purchased or our factory Customer
Service Department if you need help troubleshooting, obtaining parts, or locating an authorized ROLAIR
service representative.
To order replacement parts:
Make a permanent record of the model and serial number of your new air compressor here. You'll save time and
expense by including this reference information when requesting service or replacement parts.
Place & Date of Purchase
Model
Serial #
With the tank gauge at 0 PSI and air line(s) disconnected, close drain valve(s) and record the amount of time it takes
to build tank pressure on the space provided. Periodically test your air compressor against this pump-up time to
determine if it is operating correctly. If time test is considerably off, contact your local ROLAIR representative to
arrange service.
Date
606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 920.349.3281 > fax 920.349.3691 > www.rolair.com
OWNER'S MANUAL
WARNING
1.
Give compressor model number
2.
Give compressor serial number
3.
Name of part
4.
Part number
5.
Quantity required
RECORD OF PERTINENT INFORMATION
From 0 to ______*PSI
Min
Sec
PARTS
Volts
HZ
HP
From 0 to ______*PSI
Date
Min
- 1 -
Sec

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OILLESS AIR COMPRESSOR and is the answer not in the manual?

Questions and answers

Summary of Contents for Rolair OILLESS AIR COMPRESSOR

  • Page 1 If time test is considerably off, contact your local ROLAIR representative to arrange service. From 0 to ______*PSI From 0 to ______*PSI Date Date 606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 920.349.3281 > fax 920.349.3691 > www.rolair.com - 1 -...
  • Page 2 We are committed to continuing this tradition by analyzing and adapting to the changing needs and rigorous demands of your industry. You can depend on ROLAIR because they are built to last. This manual was compiled for the benefit of the operator. Do not use or allow anyone else to use your air compressor until this manual is read and all safety/operating instructions are understood.
  • Page 3: Safety Warnings

    SAFETY WARNINGS READ AND UNDERSTAND ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR Hazard Level Potential of Hazard How to Avoid Hazard Serious injury or death may occur from Never inhale compressed air directly from the inhaling compressed air. The air stream may pump, receiver, or from a breathing device contain carbon monoxide, toxic vapors, or connected to the air compressor.
  • Page 4 SAFETY WARNINGS (con’t) Never operate the air compressor without Serious injury may occur from moving parts protective belt guards installed. Replace such as belts, pulleys, flywheels or fans if they damaged protective covers or guards came in contact with you or your clothing. immediately.
  • Page 5: System Controls

    (8) CHECK VALVE Every ROLAIR air compressor is built with a check valve to seal off and maintain tank pressure after the top load- end setting of pressure switch is reached. The check valve works in conjunction with the solenoid relief valve to provide a less start for the compressor system.
  • Page 6 PRE-START CHECKLIST Read the owner’s manual thoroughly. Make sure that you completely understand all of the safety warnings, system controls and instructions provided before attempting to operate this air compressor. Every effort has been made to provide you with the information needed to obtain many years of reliable and trouble-free service out of your new air compressor.
  • Page 7 – WARNING Your safety and the wellbeing of others during the operation of every ROLAIR compressor is our main concern. Do not operate or permit anyone else to operate your air compressor until the information contained in this manual is read and completely understood. Please contact your distributor or our customer service department if you have any questions on the proper use of your air compressor.
  • Page 8: Troubleshooting

    TROUBLESHOOTING WARNING Make sure you completely understand all of the safety warnings and operation of each system control component before attempting any maintenance or repair. Always drain the tank pressure completely, make sure the power cord is unplugged, and unit has time to cool before performing any maintenance or service operations.
  • Page 9 Our line covers the complete needs of today’s varied air requirements. Rely on ROLAIR for all the newest and finest features that are available for the modern compressor. 606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 920.349.3281 > fax 920.349.3691 > www.rolair.com 4/11...
  • Page 11 Box Connector JC800-27 Washer JC800-57 Bolt JC800-28 Bolt JC800-58 Bolt JC800-29 Drain Valve JC800-59 Washer JC800-30 Cord with Plug JC800-60 606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 920.349.3281 > fax 920.349.3691 > www.rolair.com 3/11...

This manual is also suitable for:

Jc10

Table of Contents