6.2 PATH OF WATER INTAKE - "LONG TANK"

From the solenoid valve (2/3), the water is ducted into the fill tank and across the air break (5) into the
steam condenser (6) until the condenser is full.
-
When the condenser is full to overflowing, and the softener system is featured, the water is ducted
through a channel into the regeneration chamber (7). In this case, too, once the overflow level is
reached, the water is divided into two parts ducted through two separate channels.
-
Part of the water passes through one channel directly to the softener (9) (resin container), from
which the softened water continues towards the sump.
-
A smaller quantity of water is collected in one of the channels for use in the "Blending" function
(refer to section 6,6 - "Definition of the Regeneration System"), where it is ducted directly into the
tub through the steam venting ring.
N.B. -
The steam condenser (6), once full of water, remains filled. With each subsequent fill, the
incoming water replaces the water previously present in the condenser.
-
The steam condenser (6) is drained through the fill hose (1/2) by a vacuum effect, after
disconnecting it from the intake tap and laying it on the floor.
With Softener
Without Softener
KEY
1 - Fill hose
2 - Fill hose with "Aquacontrol" device
3 - Fill solenoid
4 - Regeneration solenoid
5 - Air-Break
6 - Steam condenser
7 - Regeneration chamber
8 - Salt reservoir
9 - Resin reservoir
10 - Level pressure switch
SOI/TD - PR
11 - Anti-overflow pressure switch
12 - Sump assembly
13 - Washing pump
14 - Tube-enclosed heating element
15 - Drain pump
16 - Non-return valve
17 - Drain hose
18 - Drying duct/Fan
19 - Anti-flooding device