6 HYDRAULIC CIRCUIT

6.1 PATH OF WATER INTAKE - "SHORT TANK"

From the solenoid valve (2/3), the water is ducted into the fill tank and across the air break (5) into the
regeneration chamber (7) until the chamber is full.
Once the chamber is full to overflowing, and the softener system is featured, the water is divided into
two parts through two separate channels.
-
One channel ducts the water directly into the softening system (9) (resin container), from where the
softened water continues towards the sump.
-
A smaller quantity of water is collected in one of the channels for use in the "Blending" function
(refer to section 6.6 - "Definition of the Regeneration System"), where it is ducted directly into the
tub through the steam venting ring.
With Softener
Without Softener
KEY
1 - Fill hose
2 - Fill hose with "Aquacontrol" device
3 - Fill solenoid
4 - Regeneration solenoid
5 - Air-Break
6 - Steam condenser
7 - Regeneration chamber
8 - Salt reservoir
9 - Resin reservoir
SOI/TD - PR
10 - Level pressure switch
11 - Anti-overflow pressure switch
12 - Sump assembly
13 - Washing pump
14 - Tube-enclosed heating element
15 - Drain pump
16 - Non-return valve
17 - Drain hose
18 - Anti-flooding device