b. 230V Installation
Notes:
• Receiver unit should have a permanent 230V AC main supply
• Confirm that the Boiler is configured for 230V switching
PLEASE DO NOT SWITCH THE RECEIVER ON UNTIL YOU ARE READY TO PAIR WITH THERMOSTAT
RF PAIRING
Switch on receiver and the RED LED should start flashing. If receiver was already switched on, switch
OFF then back ON again the RED LED should start flashing.
Now press and hold the SYNC button on the rear of the thermostat for 3
seconds. The LED below the dial will start flashing.
Now check the LED on the receiver, once RF pairing is successful the LED
on the receiver will stop flashing
Now press and hold the SYNC button on the thermostat for 3 seconds.
The thermostat should now be paired with the receiver.