setup screen
4. Select a desired <Defined Area Based Rules>.
You can specify up to 3 defined area event rules.
• Entering : An event where a moving object passes through the defined area and
enters inside will be detected.
• Exiting : An event where a moving object passes through the defined area and
exits outside will be detected.
• Appearing/Disappearing : An event will be detected where an object that has not
existed in the area until the previous frame, suddenly appears or disappears in the
area without passing through the defined area.
5. Click [OK].
To cancel the specified area, right-click on the area and select [Delete] in the context
menu.
6. When done, click [Apply (
To use the IV analysis function according to the whole area based rule
1. Set <IV analysis function> to
<Enable>.
2. If you set the event rule to <Entire
area based rules>, this will display the
popup window.
3. Select a desired <Entire Area Based
Rules>.
• Appearing : An event where an
object that has not existed suddenly appears will be detected.
• Disappearing : An event where an object that has existed suddenly disappears
will be detected.
• Scene Change : An event where the screen is changed at more than a certain
time interval will be detected.
You can set the <Scene Change> rule along with rules : <Appearing> and <Disappearing>.
4. Click [OK].
5. When done, click [Apply (