ELECTRICAL ADJUSTMENT PROCEDURE
AMP SECTION
1. OFF SET VOLTAGE
A. Setting
Set the master volume controls minimum.
B. Connection
C. Adjustment
Control OFFSET until voltmeter is the "0" position.
2. IDLE CURRENT
A. Setting
Set the master volume controls minimum.
B. Connection
C. Adjustment
Adjust IDLE so that the current through the R56, R57, R58, R59 become 10 milliampere. When that
voltage across the IDLE2 TO IDLE3 becomes 10 millivolt, the current becomes 10 milliampere.