Mitsubishi Electric MSZ-GB35VA Operating Instructions Manual
Mitsubishi Electric MSZ-GB35VA Operating Instructions Manual

Mitsubishi Electric MSZ-GB35VA Operating Instructions Manual

Split-type air conditioners
Hide thumbs Also See for MSZ-GB35VA:

Advertisement

SPLIT-TYPE AIR CONDITIONERS

OPERATING INSTRUCTIONS

INDOOR UNIT
MSZ-GB35VA
For customers
Thank you very much for purchasing this Mitsubishi room air conditioner.
• To use this unit correctly and safely, be sure to read this operating instructions before use. Keep this manual carefully for later reference.
• Be sure to receive a guarantee card from your dealer and check that the purchased data and shop name, etc. are entered correctly.
• This air conditioner should not be installed by the customer. (Safety and performance functions cannot be assured.)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MSZ-GB35VA

  • Page 1: Operating Instructions

    MSZ-GB35VA For customers Thank you very much for purchasing this Mitsubishi room air conditioner. • To use this unit correctly and safely, be sure to read this operating instructions before use. Keep this manual carefully for later reference. • Be sure to receive a guarantee card from your dealer and check that the purchased data and shop name, etc. are entered correctly.
  • Page 2: Table Of Contents

    CONTENTS • SAFETY PRECAUTIONS ................................ 2 This air conditioner is NOT intended for use by children or infirm persons without supervisions. NAME OF EACH PART ................................3 PREPARATION BEFORE OPERATION ..........................4 WARNING AUTO CHANGEOVER... AUTO MODE OPERATION ......................6 Do not use intermediate connection of the power supply cord or the extension cord and do not MANUAL OPERATION (COOL, DRY, HEAT) ..........................
  • Page 3: Name Of Each Part

    SAFETY PRECAUTIONS NAME OF EACH PART Indoor unit CAUTION Do not use the unit for special purposes. Air inlet • Do not use this air conditioner to preserve precision devices, food, animals, plants and art objects. This Heat exchanger Front panel may cause deterioration of quality, etc.
  • Page 4: Preparation Before Operation

    NAME OF EACH PART PREPARATION BEFORE OPERATION Remote controller Auto restart function These models are equipped with an auto restart function. If you do not want to use this function, please consult the service representative because the setting of the unit needs to be changed. Signal transmitting section Auto restart function is ...
  • Page 5: Emergency Operation

    PREPARATION BEFORE OPERATION Remote controller When the remote controller cannot be used (emergency operation) Handling of the remote controller • The range that the signal can reach is about 6 m When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation How to set the batteries and the current time when the remote controller is pointed at the front of the indoor unit.
  • Page 6: Auto Changeover

    AUTO CHANGEOVER... AUTO MODE OPERATION An automatic cooling and heating changeover operation system ensures easy control and year-round Description of “AUTO RESTART FUNCTION” air conditioning. Once the desired temperature is set, unit operation is switched automatically between cooling and • These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start heating according to the room temperature.
  • Page 7: Manual Operation (Cool, Dry, Heat)

    MANUAL OPERATION (COOL, DRY, HEAT) AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT AIR FLOW velocity and direction can be selected as required. To select the COOL, DRY or HEAT mode: ON/OFF To change the AIR FLOW velocity, press the button. Press the button.
  • Page 8 AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT Movement of the horizontal vane To change the horizontal direction of the air flow, move the vertical vane manually. COOL/DRY HEAT At the start of heating operation When air becomes Horizontal Very small Horizontal position warm…...
  • Page 9: Econo Cool Operation

    ECONO COOL OPERATION WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME Use this operation when you want to be comfortable in COOL mode even with energy saved. Perform the following operations while the unit is operating When it is not going to be used for a long When the air conditioner is to be used in the MANUAL COOL mode.
  • Page 10: Cleaning The Front Panel, Heat Exchanger And Fan

    CLEANING THE FRONT PANEL, HEAT EXCHANGER AND FAN CLEANING THE CATECHIN AIR FILTER Front panel Heat exchanger Cleaning the catechin air filter (about once every 2 weeks) Remove the catechin air filter. After washing with water/lukewarm water, dry Hold both ends of the front panel and lift the Remove the catechin air filter before cleaning the catechin air filter well in the shade.
  • Page 11: Cleaning The Air Cleaning Filter

    CLEANING THE AIR CLEANING FILTER REPLACEMENT OF THE AIR CLEANING FILTER When the capacity is lowered because of dirt, etc., it is necessary to replace the air cleaning filter. Cleaning the air cleaning filter (about once every 3 months) Remove the catechin air filter (left one). Air cleaning filter replacement (about once every year) Soak the filter together with its frame in luke- warm water and wash it.
  • Page 12: Cleaning The Air Outlet And Fan Of The Indoor Unit

    CLEANING THE AIR OUTLET AND FAN OF THE INDOOR UNIT Clean the air outlet and fan of the indoor unit. (Make sure the fan has stopped.) Before cleaning Switch the indoor unit off with the remote controller and disconnect the power supply plug and/or turn off the breaker, otherwise you may get injured since the fan of the indoor unit rotates at high speed during operation.
  • Page 13: Before Contacting The Service Representative, Check The Following Again

    BEFORE CONTACTING THE SERVICE REPRE- WHEN YOU THINK THAT TROUBLE HAS OCCURRED SENTATIVE, CHECK THE FOLLOWING AGAIN Question Answer (not a malfunction) Question Answer (not a malfunction) The air conditioner cannot • This protects the air conditioner according to The air flow direction •...
  • Page 14: Installation, Relocation And Inspection

    CLEANING THE AIR OUTLET AND FAN OF THE INDOOR UNIT CAUTION: Installation place The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets, • Earth the unit. radios, etc. In areas where the reception is weak, pro- Inverter-type vide greater space between the outdoor unit and the Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone.
  • Page 16 HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODAKU, TOKYO 100-8310, JAPAN SG79Y987H01...