Philips FPF32C106128UA-51 Service Manual

Colour television

Advertisement

Colour Television

©
Copyright 2005 Philips Consumer Electronics B.V. Eindhoven, The Netherlands.
All rights reserved. No part of this publication may be reproduced, stored in a
retrieval system or transmitted, in any form or by any means, electronic,
mechanical, photocopying, or otherwise without the prior permission of Philips.
Published by MW 0570 TV Service
FHP PDP Repair Manual
FPF32C106128UA-51, -52, -62 (32" H1)
Contents
Printed in The Netherlands
FPF32C106128UA-72 (32" H2)
FPF37C128128UA-72 (37" H2)
FPF37C128128UB-72 (37" A1)
FPF42C128128UB-54 (42" H1)
FPF42C128128UB-72 (42" H2)
FPF42C128128UC-52 (42" A1)
FPF42C128128UD-52 (42" A2)
FPF42C128128UE-52 (42" A3)
Page
2
5
7
7
33
35
35
36
37
38
Subject to modification
Module
EN 3122 785 14582

Advertisement

Table of Contents
loading

Summary of Contents for Philips FPF32C106128UA-51

  • Page 1: Table Of Contents

    All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise without the prior permission of Philips. Published by MW 0570 TV Service...
  • Page 2: Technical Specifications

    1.1.5 42” H1 1.1.1 32” H1 No Item Spec. FPF42C128128UB-54 Information not available Pixel No Item Spec. FPF32C106128UA-51,-52,-62 Number of Cells Information not available Pixel Pixel Pitch Number of Cells Cell Pitch Pixel Pitch Display size Cell Pitch Screen size...
  • Page 3 Technical Specifications FHP PDP EN 3 Serial Numbers No Item Spec. FPF42C128128UD-52 Weight About 16 kg Check the serial ID number of the product requested for repair, 10 H sync, V sync, data 50kHz (H), 50/60/70Hz (V), LVDS before starting the problem analysis and repair. 1.1.9 42”...
  • Page 4: Technical Specifications

    EN 4 FHP PDP Technical Specifications Chassis overview PSU BOARD Y-SUS BOARD X-SUS BOARD SCAN MODULE ABUSL BOARD ABUSR BOARD ADM1 ADM2 ADM3 ADM4 ADM5 ADM6 ADM7 ADM8 LOGIC BOARD ADRESS MODULE (ADM) E_14580_001.eps 310304 Figure 1-4 PWB locations...
  • Page 5: Safety Instructions, Warnings, And Notes

    Safety Instructions, Warnings, and Notes FHP PDP EN 5 2. Safety Instructions, Warnings, and Notes Index of this chapter: 2. Never disconnect the power display cable when the set is 2.1 Safety Instructions operating 2.2 Warnings 3. With DST no failures (error-codes) can be red, when the 2.3 Notes set is in Service-mode.
  • Page 6 EN 6 FHP PDP Safety Instructions, Warnings, and Notes • Perform a safety check when servicing is completed. Verify that the peripherals of the serviced points have not undergone any deterioration during servicing. Also verify that the screws, parts and cables removed for servicing purposes have all been returned to their proper locations in accordance with the original setup...
  • Page 7: Directions For Use

    Directions for Use FHP PDP EN 7 3. Directions for Use Not applicable. 4. Mechanical Instructions Index of this chapter: 4.1.2 X-SUS Circuit Board 4.1 Board Swap Instructions Notes: • Figures below can deviate from the actual situation, due to different set executions.
  • Page 8 EN 8 FHP PDP Mechanical Instructions 3. Disconnect the connectors CN22, CN23 and CN26. 4.1.4 ABUS-L Circuit Board 4. Pull out the XSUS board horizontally and disconnect the connectors (CN24, CN25). (3)CN51 5. Remove the X-SUS board. (1)CN52 Make sure that you do not touch the heat sink when removing the Y-SUS board.
  • Page 9 Mechanical Instructions FHP PDP EN 9 F_14582_013.eps F_14582_015.eps 300905 300905 Figure 4-9 ABUS-R board removal (2) Figure 4-11 Logic board removal (2) Remove the circuit board by following the steps below. To Remove the circuit board by following the steps below. To install the circuit board, reverse the removal procedure.
  • Page 10 EN 10 FHP PDP Service Modes, Error Codes, and Fault Finding 5. Service Modes, Error Codes, and Fault Finding Index of this chapter: 5.1 Repair Tools 5.2 Process Flow 5.3 Repair Instructions 5.4 Defect Description Form Repair Tools To be able to repair the Plasma Display Panels on board level, the following repair tools are available: •...
  • Page 11 Service Modes, Error Codes, and Fault Finding FHP PDP EN 11 Process Flow the defective PDP, accompanied by a completely filled in Defect Description Form (see figure “Defect Description Form (DDF)“), in this flight case to EuroService. EuroService makes The selected workshop receives the defect TV set and sure the defect PDP is repaired and afterwards added to its investigates the PDP.
  • Page 12: Repair Instructions

    From AG06 0242 onwards These Plasma Display Panels are used in FM24 sets with production code AG00 and higher. The available modules for the Plasma Display Panel FPF32C106128UA-51 and -52 are: The involved Plasma Display Panel is: Factory code Service code...
  • Page 13 Service Modes, Error Codes, and Fault Finding FHP PDP EN 13 5.3.7 42” H2 ALiS Plasma Display Panel 5.3.10 42” A3 ALiS Plasma Display Panel These Plasma Display Panels are used in FM24 sets with The involved Plasma Display Panel is: production code: Display type Service code number...
  • Page 14 EN 14 FHP PDP Service Modes, Error Codes, and Fault Finding 5.3.11 Fault Finding Flowcharts Problem analysis procedure PDP repair / Board swap PDP Repair procedure Board Swap The entire Screen does not light. The set is going into protection. Vertical Line / Vertical Bar? Horizontal bar? (PSU is OK)
  • Page 15 Service Modes, Error Codes, and Fault Finding FHP PDP EN 15 Problem Analysis Procedure the entire screen does not light. The entire screen does not light Caution: never disconnect connectors or remove boards when the mains plug is connected. Allow discharge of power supplies before disconnecting connectors! All the boards are connected Connect the set to mains.
  • Page 16 EN 16 FHP PDP Service Modes, Error Codes, and Fault Finding Short-circuit check on Power Supply Lines Check with an ohmmeter if following pins are not shorted X-Sus Board CN23 VCC pins 3 - 4 X-Sus board is defective Vs pins 6 - 8 Va pins 1 - 4 Replace X-Sus board are shorted?
  • Page 17 Service Modes, Error Codes, and Fault Finding FHP PDP EN 17 Short-circuit check on Power Supply Lines ABUSR Board Va CN42 pins 1 - 4 Vcc CN42 pins 5 -7 are shorted? Remove ADM from the following connectors CN43, CN44, CN45, CN45 ABUSR Board Va CN42 pins 1 - 4 ADM is defective...
  • Page 18 EN 18 FHP PDP Service Modes, Error Codes, and Fault Finding 5V Vcc check ABUSR, ABUSL, Y-Sus, X-Sus board In the next steps the 5V Vcc power supply lines will be checked. AExternal Power Supply is connected to D6224/D6225 5V Vcc on the set PS. Set is disconnected from AC mains! For testing each board, ramp up the External PSU from 0 to 5V.
  • Page 19 Service Modes, Error Codes, and Fault Finding FHP PDP EN 19 VA check on the ABUSR and ABUSL board Va and Vs Check with internal PSU Connect the set to AC Mains. For each step switch the set off and on via the vacation swith and the RC Switch on PSU board Va 50V...
  • Page 20 EN 20 FHP PDP Service Modes, Error Codes, and Fault Finding Vs Check on Y-Sus & X-Sus board and SDM / XBB Remark: There is no start up of Vs switched and Va if power supply to X-Sus (CN23) or Y-Sus (CN33) board is disconnected PSU board PSU Board Va block is defective Vs 80V exists?
  • Page 21 Service Modes, Error Codes, and Fault Finding FHP PDP EN 21 Vs Check on Y-Sus & X-Sus board and SDM / XBB There is a posibility to check the VS and Va power supply lines via an external power supply. External power supply connected to VS or Va power supply line and ground, output voltage = 20V, current = 0mA or very low current to charge the capacitors at switch on.
  • Page 22 EN 22 FHP PDP Service Modes, Error Codes, and Fault Finding Vertical Line / Vertical bar Problem analysis procedure Vertical line / Vertical bar Logic - ABUS board signal cable has abnormal Signal cable is defective. appearance? ADM flexible has ADM is defective abnormal appearance? PDPs is defective...
  • Page 23: Service Modes, Error Codes, And Fault Finding 10

    Service Modes, Error Codes, and Fault Finding FHP PDP EN 23 Bar of 1/2 screen width on the left does not light? Voltage exists at Logic board is ABUSL board CN52? defective Switch off Disconnect CN52 from ABUSL board Switch on Voltage exists ABUSL board is at PSU board?
  • Page 24 EN 24 FHP PDP Service Modes, Error Codes, and Fault Finding Vertical line of different color? Exists in left 1/2 area? Switch off. Replace ABUSL board. Switch on ABUSL board is Normal? defective Switch off Replace Logic board Switch on LOGIC board is Normal? defective.
  • Page 25 Service Modes, Error Codes, and Fault Finding FHP PDP EN 25 Switch off Replace ABUSR board Switch on ABUSR board is Normal? defective Switch off Replace Logic board Switch on Logic board is Normal? defective Switch on Replace signal Cables Logic - ABUSR Switch on Signal cable is Normal?
  • Page 26 EN 26 FHP PDP Service Modes, Error Codes, and Fault Finding Horizontal bar problem analysis procedure Horizontal bar Switch off Replace X-Sus board Switch on Normal? X-Sus board is defective Switch off Replace X-Sus board (original board) Replace Y-Sus board Switch on Normal? Y-Sus board is defective...
  • Page 27 Service Modes, Error Codes, and Fault Finding FHP PDP EN 27 Remark: Do not interchange boards between different PDPs, this can damage your PDP Logic Board Exchange (1) 1. Copy NVM Data from defective Logic Board Unscrew the SCAVIO Panel Disconnect the LVDS Cable from the SCAVIO at (CN0301) Connect the service Cable (12nc 9965 000 23434) to...
  • Page 28 EN 28 FHP PDP Service Modes, Error Codes, and Fault Finding Logic Board Exchange (2) 2. Write NVM Data to the new Logic Board Switch off the set and replace the Logic board And connect the service cable to the SCAVIO (CN0301) Switch the set on with the RC and bring the set in CSM using code 123654 Click the "On"...
  • Page 29 Service Modes, Error Codes, and Fault Finding FHP PDP EN 29 No Fault contents Fault status Suspected fault Analysis location procedure and measure After momentarily X-SUS, Y-SUS Refer to the entire going on, the screen screen does not becomes black Panel chassis light.
  • Page 30 EN 30 FHP PDP Service Modes, Error Codes, and Fault Finding No Fault contents Fault status Suspected fault Analysis location procedure and measure Bar width of 1/8 or Panel chassis Replace panel multiples of 1/8 of the chassis screen height, is displayed Abnormal (Screen does light) Horizontal bar...
  • Page 31 Service Modes, Error Codes, and Fault Finding FHP PDP EN 31 No Fault contents Fault status Suspected fault Analysis location procedure and measure LOGIC Replace LOGIC Picture board and folow distorted Logic Board Luminance linearity is LOGIC Steps of echange poor.
  • Page 32 The defective LCD-panel / PDP needs to be returned in the same packaging as the new part was send. If not the warranty claim will be rejected. Note 2: Please fill out this form completely and correctly, otherwise Euroservice is unable to fulfil the repair request! Owner: PHILIPS CE EUROSERVICE DE10WEG F_15590_115.eps 110705...
  • Page 33: Block Diagrams, Test Point Overview, And Waveforms

    Block Diagrams, Test point Overview, and Waveforms FHP PDP EN 33 6. Block Diagrams, Test point Overview, and Waveforms Block Diagrams X-SUS B. Y-SUS B. X-SUS Y-SUS EVEN SW EVEN SW X-SCAN Y-SCAN EVEN SW EVEN SW X-SUS Y-SUS ODD SW ODD SW X-SCAN Y-SCAN...
  • Page 34: Test Points

    EN 34 FHP PDP Block Diagrams, Test point Overview, and Waveforms X-SUS B. Y-SUS B. X-SUS Y-SUS EVEN SW EVEN SW X-SCAN Y-SCAN EVEN SW EVEN SW X-SUS Y-SUS ODD SW ODD SW X-SCAN Y-SCAN ODD SW ODD SW ADM1 ADM2 ADM3 ADM4...
  • Page 35: Circuit Diagrams And Pwb Layouts

    Circuit Diagrams and PWB Layouts FHP PDP EN 35 7. Circuit Diagrams and PWB Layouts Not applicable. 8. Alignments Index of this chapter: 8.1 Voltage Setting Procedure Voltage Setting Procedure On the back of the PDP, in the top right hand corner, you find the Voltage Setting label: <...
  • Page 36: Circuit Descriptions, Abbreviation List, And Ic Data Sheets

    EN 36 FHP PDP Circuit Descriptions, Abbreviation List, and IC Data Sheets 9. Circuit Descriptions, Abbreviation List, and IC Data Sheets Index of this chapter: 9.1.3 Function of Y-SUS Board 9.1 Board Function Description 9.2 List of Abbreviations DC/DC Power Supply Block •...
  • Page 37: Spare Parts List

    Spare Parts List FHP PDP EN 37 List of Abbreviations Plasma display panel abbreviated Probe A cable with contact finger that can transfer the status of the electric circuit Address module to be measured to an oscilloscope Burn-in rack Test equipment of the shelf test in Protection cover A cover made of aluminium to protect which the PDP unit is left to stand in...
  • Page 38: Revision List

    EN 38 FHP PDP Revision List 11. Revision List Supplement on the following service manuals: Table 11-1 Overview of chassis and manuals, covered by Display type Model # Chassis Manual # this manual 42FD9934/17S FM24 AA 312278513891 42FD9934/69S FM24 AA 312278513891 Display type Model # Chassis...

Table of Contents