CMC 30 HP30 Installation And Operation Instruction Manual page 49

Cmc ac variable speed drive 1 -30 hp (230/460v)
Table of Contents

Advertisement

FU2-40
No
All
Rs+Lsigma
Enc Test
Tr
6) Sensorless vector control
Set FU2-39 to 2 {Sensorless_S} or 3 {Sensorless_T} to enable Sensorless vector control. It is strongly recommended to
perform Auto-tuning for Sensorless before starting Sensorless control in order to maximize performance. Two types of
Sensorless vector control are available; Sensorless_S or Sensorless_T.
Parameter Name
Control mode selection
P, I gain for sensorless
control
Starting freq
7) Vector control
Set FU2-39 to 4 {Vector_SPD} or 5{Vector_TRQ} to enable Vector control. Encoder should be installed to the motor with
Sub-B or Sub-D boards in the inverter to start this control.
Parameter Name
Usage of Pulse Input
Signal
Pulse Input Signal
Selection
Encoder Pulse Number
Motor constants calculation disabled
All constants can be measured in this code but different constants are tuned
according to control mode type;
For V/F, Slip compen , Sensorless_S, Sensorless_T:
(No-load current, stator resistance, leakage inductance, stator inductance
available)
Note) Only no-load current can be calculated during V/F and Slip compensation.
For Vector_SPD, Vector_T:
No-load current, stator resistance, leakage inductance, stator inductance,
encoder test, rotor filter time constant
Calculate stator resistance, leakage inductance
Calculate the encoder status
Calculate Rotor filter time constant
Code
FU2-39
Select Sensorless_S or Sensorless_T
FU2-45, FU2-46
Setting gain for Sensorless_S control
FU1-22
Starting freq of the motor
Code
Defines the method of pulse input with SUB-B or SUB-D
EXT-12
boards mounted. Vector control setting is valid only after
this parameter is set to 1 {Feed-back}.
3 types of pulse input : (A+B), A, -(A+B)
EXT-15
EXT-16
Enter the pulse number of encoder in the motor.
Description
Description
Description
4-3
Chapter 4 – Function Settings