Maintenance; Gas Pressure Adjustment; Venturi Adjustment - Napoleon Torch GT8N Installation And Operation Instructions Manual

Vented gas fireplace
Table of Contents

Advertisement

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE
SERVICING THE FIREPLACE.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing. This fi replace
and its venting system should be inspected before use and at
least annually by a qualifi ed service person. The fi replace area
must be kept clear and free of combustible materials, gasoline
or other fl ammable vapours and liquids. The fl ow of combustion
and ventilation air must not be obstructed.

GAS PRESSURE ADJUSTMENT

Outlet pressure can be adjusted if not measuring 3.5" W.C.
(NG) or 10.0" W.C. (LP).
1. Pressure can be
checked by removing
cap (A) using
a 3/16 allen key and
replacing it with a 1/8
NPT barb fi tting.
2.
Place pressure
gauge tube over the
fi tting.
3. Pressure can be
adjusted by removing
cap (B) using a fl at
screwdriver,
and
adjusting the nylon
plug with the same
screw driver. Turning
the plug in (clockwise)
will
increase
the
pressure.
NorthlineExpress.com

MAINTENANCE

1. Keep the control compartment, burner, and air shutter opening
clean by vacuuming or brushing, at least once a year.
2. Check to see that the main burner ignites when the switch
for the burner is turned on. A 5 second light-up period is satis-
factory. If ignition takes longer, consult your Napoleon® dealer
/ distributor.
3. Check that the gasketing on the sides, top and bottom of the
door is not broken or missing. Replace if necessary.
ADJUSTMENTS
Closing the air shutter will cause a more yellow fl ame, but can
lead to carboning. Opening the air shutter will cause a more
blue fl ame, but can cause fl ame lifting from the burner ports.
FIGURE 33
The fl ame may not appear yellow immediately; allow 15 to 30
minutes for the fi nal fl ame color to be established.
NOTE: It is important that
the venturi sits down tight
on the orifi ce. The burner
is adjustable up/down to
ensure this.
FIGURE 35
FIGURE 34
It is important to periodically
perform a visual check of the
burner fl ame. Compare them to
the illustration provided.
http://www.northlineexpress.com

VENTURI ADJUSTMENT

AIR SHUTTER OPENINGS
LP
NG
FLAME CHARACTERISTICS
FIGURE 36
19
5/16" DIA (x2)
3/16" DIA (x1)
W415-0619 / B / 03.03.08
Toll-Free 1-866-667-8454

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Torch gt8p

Table of Contents