6. WARRANTY

6.1. Compressor warranty :
Our compressors are warranted for 12 months from the delivery of the goods starting from the date showed in the documents.
Warranty is valid only if the buyer respects all contract rules and the compressor is used according to our indications.
Warranty is excluded for:
Bad use
The spares necessaries for a periodically maintenance.
The use of not original spares.
Other gas different to air or with more of 21% oxygen.
Reparation must be made inside Nardi factory and the compressors must always delivered at the buyer's charges and risks. Otherwise, in
case of outside reparation all transport costs will be debted to the buyer (only trained personnel can work with the machine). If the reparation
needs of a Nardi technician, all trip charges must be debted to the buyer.
7. INSTALLATION, OPERATION, FILLING PROCEDURE

7.1. Installation of the compressor unit:

The compressor frame is equipped with anti-vibration mounts. The compressor is not seawater resistant . At operation in salty air spray com-
pressor with anticorrosive protection. Electric driven units should be operated and stored below deck. Units with petrol engine should also be
stored below deck after the filling process. Take care with the electrical unit.

7.2. Outdoor location:

For installation observe the following:
Locate the unit level in a good and safety place.
Only clean air must be used. For petrol engine is important to position compressor in direction of wind so that exhaust fumes are
blown away from the unit. It is good practice to have an intake hose with pre-filter and intake filter. Pre filter to be located high above
ground. This arrangement will ensure necessary spacing between exhaust outlet and air inlet. On petrol or diesel engine, operation
unit must only be located outdoors, never indoors.
Do not operate unit in the vicinity of open fire(flue gas).

7.3. Indoor location:

Ensure adeguate ventilation. Air must be free from exhaust fumes and hazard-ous vapours (smoke, gas, solvent vapours and so on.) Do not
smoke inside the operation room. If possibile install unit such a manner that the compressor fan can get fresh air from outside. Open the wall
if necessary. Never operate petrol driver units indoor!
INSTRUCTION MANUAL PACIFIC 210