TSTAT0406 & TSTAT0407 997-060180-5 Installation Instructions / User’s Manual TSTAT0406 and TSTAT0407 4 HEAT – 2 COOL – DUAL FUEL TSTAT0406 & TSTAT0407 - 4 WIRE CAPABLE THERMOSTAT (NAXA00101DB Daughter Board sold separately) LEFT OR PREVIOUS UP BUTTON SCREEN BUTTON SELECT BUTTON...
Page 2
TSTAT0406 & TSTAT0407 TSTAT0406 AND TSTAT0407 MENU MAP MODEL INSTALLER CONFIGURATION HEAT/COOL SINGLE STAGE ELECTRIC SETTINGS MULTI STAGE ELECTRIC HEAT PUMP SINGLE STAGE ELECTRIC DUAL FUEL MULTI STAGE ELECTRIC DUAL FUEL ACCESSORIES AIR FILTER CUMULATIVE RUN TIME HOURS CALENDER TIME...
DOWN STAGING – You can turn down staging on or off. Default is on. (Refer to down staging section for details) Staging Properties: Thermostat models TSTAT0406 & TSTAT0407 use advanced logic to control a two-stage heating or cooling system for better home comfort and higher efficiency. The thermostat continuously monitors set point, room temperature, anticipator setting, and temperature rate-of-change.
Page 4
TSTAT0406 & TSTAT0407 gas or oil, highlight the DUAL FUEL option. For electric add-on heat, highlight ELECTRIC. Pressing the SELECT button finishes the system configuration and returns the display to the INSTALLER SETTINGS MODEL CONFIGURATION screen. ELECTRIC NOTE: The configuration steps must be done at the initial installation of the thermostat or CONFIGURATION ERROR will appear on the top line of the MAIN SCREEN.
TSTAT0406 & TSTAT0407 Highlighting the type of information to enter and pressing SELECT button brings up the DATA ENTRY screen for that option. Use the UP and DOWN buttons to scroll through the letters and numbers and use DEALER INFO the RIGHT button to move to the next space.
TSTAT0406 & TSTAT0407 TEMPERATURE OFFSETS TEMPERATURE OFFSETS TEMPERATURE OFFSET Highlighting the TEMPERATURE OFFSETS and pressing SELECT will bring up the TEMPERATURE OFFSET screen. Selecting which offset to adjust and pressing SELECT will bring up the appropriate screen for the TEMPERATURE OFFSET TEMPERATURE OFFSET 0°...
TSTAT0406 & TSTAT0407 HEAT PUMP LOCKOUT – Does not allow the heat pump to operate when the outdoor temperature is below a specified temperature. SMART RECOVERY Highlighting the SMART RECOVERY option and pressing SELECT will bring up the SMART RECOVERY SMART RECOVERY screen.
⊲ PREVIOUS SERVICE NEEDED SCREEN SERVICE NEEDED Anytime there is an active fault on the Comfort Alert module and the “L” input is wired to the TSTAT0406, CALL: TSTAT0407 thermostats or NAXA00101DB Daughter Board, the thermostat display will display the XXXXXXXXXXXXXXX SERVICE NEEDED screen with the corresponding Comfort Alert Fault.
TSTAT0406 & TSTAT0407 DOWN STAGING Highlighting the DOWN STAGING option and pressing the SELECT button brings up the DOWN STAGING DOWN STAGING screen. Pressing the UP or DOWN button will alternate between ON & OFF. Selecting ON will allow the thermostat to down stage to a lower heating or cooling stage as the ambient temperature gets closer to the temperature setpoint.
TSTAT0406 & TSTAT0407 MAIN SCREEN MAIN SCREEN The Thermostat operation runs from the main screen. With the exception of the SERVICE NEEDED SCREEN, the display will revert to the Main Screen in 3 minutes if no buttons are pressed. 8/08/05...
TSTAT0406 & TSTAT0407 TEMP Selecting TEMP and pressing the SELECT button will bring up the HOLD THIS TEMPERATURE screen. HOLD THIS If the mode is set for OFF, the temperature will be the last mode set. Shown is the AUTO mode.
TSTAT0406 & TSTAT0407 SET DATE AND TIME SET DATE AND TIME SET DATE AND TIME SET DATE AND TIME SET DATE AND TIME SET DAY SET HOUR SET MONTH SET MINUTES SET YEAR CHANGE SETTING ∇∆ CHANGE SETTING ∇∆ CHANGE SETTING ∇∆...
TSTAT0406 & TSTAT0407 PROGRAMMING SCREEN To program a day, highlight the day to program and press SELECT. The display will go to the EVERY DAY PROGRAMMING SCREEN. WAKE HEAT COOL The programming screen will either have 4 events or 2 events to program depending on the EVENTS PER...
TSTAT0406 & TSTAT0407 FAHRENHEIT OR CELSIUS TEMPERATURE SCALE Highlighting the FAHRENHEIT OR CELSIUS option and pressing the SELECT button will bring up the FAHRENHEIT FAHRENHEIT OR CELSIUS screen. Use the UP and DOWN buttons to select the option desired and press the SELECT button. The display will CELSIUS convert to the selected temperature scale and return to the SETTINGS MENU.
TSTAT0406 & TSTAT0407 AUTO CHANGEOVER Highlighting the AUTO CHANGEOVER option and pressing the SELECT button will bring up the AUTO AUTO CHANGEOVER CHANGEOVER screen. Auto changeover allows the thermostat to determine if Heat or Cool should be active. AUTO CHANGOVER TIME The AUTO OR MANUAL option determines if the AUTO mode is available.
TSTAT0406 & TSTAT0407 SECURITY LOCK OUT SECURITY LOCKOUT Highlighting the SECURITY LOCKOUT option from the MAIN MENU and pressing the SELECT button will bring up the SECURITY LOCKOUT screen. TEMP ADJUST ONLY Activating the security lock out and setting a 4 digit PIN will prevent unauthorized changes to the thermostat.
Page 17
TSTAT0406 & TSTAT0407 OUTDOOR / INDOOR SENSOR INFORMATION Refer to the Outdoor Sensor literature for details. The literature is included within the sensor packet with the thermostat. NOTE: The outdoor can be used as an indoor sensor and connected to the ID and GND terminals on the back of the thermostat.
The NAXA00101DB daughter board control allows for using 4 existing thermostat wires in an existing, finished home to communicate with the TSTAT0406 & TSTAT0407 thermostats. The daughter board translates the communicated heating and cooling needs and sends the normal discrete thermostat outputs to the indoor and outdoor equipment as needed. The NAXA00101DB Daughter Board must be used in conjunction with the TSTAT406 or TSTAT0407 Communicating Thermostat for proper operation.
Page 19
Communication LED Operation The LED labeled LED3 will be illuminated for 100mS each time a successful communications packet is received from the TSTAT0406 or TSTAT0407 communicating thermostat. Thermostat Call Output LED’s Operation There is an LED Output for each thermostat output from the daughter board. The corresponding LED will illuminate any time the associated thermostat output is active.
Page 20
TSTAT0406 & TSTAT0407 GENERIC AC TO FURNACE WIRING (REFER TO UNITS I/O MANUAL FOR SPECIFICS REQUIRED OPTIONAL NOTES: 24 VAC HUM - GOES TO HUMIDIFIER, ENERGIZES ON A CALL FOR W 2 STAGE AC WITH 2 STAGE VARIABLE SPEED 1 STAGE AC WITH 1 STAGE FURNACE...