Page 1
INSTALLATION INSTRUCTIONS P/N TSTAT0712 Programmable 5-2 Day Digital Thermostat 1 STAGE HEAT COOL THERMOSTAT next prog Heat Cool Fan On Fan Auto SINGLE STAGE HEAT PUMP COMPATIBLE (Does not control auxiliary heat) Separate programs for weekdays & weekends Large, easy to read, backlit digital display...
INSTALLATION INSTRUCTIONS Safety Warnings P/N TSTAT0712 CAUTION Follow Installation Instructions carefully. DISCONNECT POWER TO THE HEATER - AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING WARNING THE NEW THERMOSTAT. CAUTION The 2 Alkaline “AA” batteries must be replaced at least every 12 months to assure proper operation.
INSTALLATION INSTRUCTIONS Step #1 Preparation Proper installation of the thermostat will be next prog accomplished by following these step Heat Cool Fan On Fan Auto by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance.
Page 5
INSTALLATION INSTRUCTIONS Remove & Replace Step #2 Old Thermostat Remove the cover of the old thermostat. next prog If it does not come off easily check for Heat Cool Fan On Fan Auto screws. Loosen the screws holding the thermostat next prog base or subbase to the wall, and lift away.
INSTALLATION INSTRUCTIONS Installation / Battery Step #3 Replacement Open The New Thermostat The top of the thermostat housing has two (2) screw- driver slots to assist when seperating. SCREWDRIVER SLOTS To pull the housing apart, insert a small blade screw- driver into the slot and rotate 90 .
These drafts, left unchecked, may cause incorrect room temperature readings. Please do not remove this label from the thermostat. Insert the wires MODEL: ICP TSTAT0712 97061606 4Z95 USE SIZE “AA” through the slots provided in the label MADE IN CHINA ALKALINE BATTERIES as shown in Fig.
INSTALLATION INSTRUCTIONS Sample Wiring Diagrams Gas or Electric Heat 4 Wire, 1 Stage Cooling, 1 Stage Gas Heat Residential Gas or Electric Heat *, Electric Cool, split systems & package units Common wire optional 4 Conductor 18 gauge unshielded cable from the thermostat to the equipment.
Page 9
INSTALLATION INSTRUCTIONS Sample Wiring Diagrams Gas or Electric Heat 4 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump with O reversing valve. Residential Heat Pumps, split systems & package units, with no auxiliary heat. Common wire optional 4 Conductor 18 gauge unshielded cable from the thermostat to the equipment.
Page 10
INSTALLATION INSTRUCTIONS Sample Wiring Diagrams Gas or Electric Heat 4 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump with B reversing valve. Residential Heat Pumps, split systems & package units, with no auxiliary heat. Common wire optional 4 Conductor 18 gauge unshielded cable from the thermostat to the equipment.
Page 11
INSTALLATION INSTRUCTIONS Sample Wiring Diagrams Gas or Electric Heat 3 Wire, 1 Stage Heat Residential Gas or Electric Heat units with a separately controlled fan. Common wire optional 3 Conductor 18 gauge unshielded cable from the thermostat to the equipment. POWER GAS VALVE STRIP HEAT...
Page 12
INSTALLATION INSTRUCTIONS Sample Wiring Diagrams Gas or Electric Heat 2 Wire, 1 Stage Gas Heat Residential Gas or Millivolt units. Common wire optional 2 Conductor 18 gauge unshielded cable from the thermostat to the equipment. POWER GAS VALVE Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by the two AA Alkaline batteries (page 14).
Page 13
INSTALLATION INSTRUCTIONS Sample Wiring Diagrams Gas or Electric Heat 3 Wire, 1 Stage Cooling Residential Electric Cool units Common wire optional 3 Conductor 18 gauge unshielded cable from the thermostat to the equipment. POWER COMPRESSOR Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by the two AA Alkaline batteries (page 14).
INSTALLATION INSTRUCTIONS Jumper Step #5 Configuration IF THERMOSTAT IS NOT SYSTEM POWERED REPLACE WITH ALKALINE BATTERIES ONCE EVERY YEAR USE “AA” SIZE USE “AA” SIZE ALKALINE BATTERIES ALKALINE BATTERIES If the HVAC unit has First Stage Electric Heat next prog then jumper should be set to ELEC.
INSTALLATION INSTRUCTIONS Step #6 Test Operation Turn on the power to the Heating/Air next prog Conditioning system. Heat Cool Fan On Fan Auto Adjust the Slide Switch until it is located next under the word HEAT on the thermostat. prog Heat Cool Fan On Fan Auto...
INSTALLATION INSTRUCTIONS Trouble Shooting SYMPTOM: The slide switches on the thermostat next are very difficult to move. prog Heat Cool Fan On Fan Auto CAUSE: The backplate of the thermostat is deformed by being screwed tightly into a wall that is not perfectly flat. REMEDY: Loosen the screws holding the thermostat into the wall.
Page 17
INSTALLATION INSTRUCTIONS Trouble Shooting SYMPTOM: The air conditioning does not next prog attempt to turn on. Heat Cool Fan On Fan Auto CAUSE: The cooling setpoint is set too high or the Mode Switch is not set for Cool, or the batteries are too weak. REMEDY: Consult the Normal Operation section of this manual to lower the cooling setpoint and to correct the...
Page 18
Finally, if the Evening Start Time is set for 5:30pm, then the Night Start Time MUST be programmed for any time AFTER the 5:30pm Night Start Time. Battery Stat P/N TSTAT0712 Tested to Comply with FCC Standards FOR HOME OR OFFICE USE 4Z95 P/N 88-429 Rev.
INSTALLATION INSTRUCTIONS Warranty One-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option, to replace any defective part will be provided without charge for the part itself;...