5. Operation
5.2. Operation mode select
Press the operation mode (
operation mode 2.
Cool mode
Dry mode
Fan mode
Heat mode <Only heat pump type>
Automatic (cool/heat) operation mode <Only heat pump type>
Ventillation mode
Only indicated on the following condition
Wired remote controller used
LOSSNAY connected
Automatic operation
According to a set temperature, cooling operation starts if the room
temperature is too hot and heating operation starts if the room
temperature is too cold.
During automatic operation, if the room temperature changes and
remains 2 °C or more above the set temperature for 15 minutes, the
air conditioner switches to cool mode. In the same way, if the room
temperature remains 2 °C or more below the set temperature for 15
minutes, the air conditioner switches to heat mode.
Cool mode
15 minutes (switches
from cooling to heating )
Because the room temperature is automatically adjusted in order to
maintain a fixed effective temperature, cooling operation is performed
a few degrees warmer and heating operation is performed a few
degrees cooler than the set room temperature once the temperature is
reached (automatic energy-saving operation).
5.3. Temperature setting
To decrease the room temperature:
Press
button 3 to set the desired temperature.
The selected temperature is displayed 3.
To increase the room temperature:
Press
button 3 to set the desired temperature.
The selected temperature is displayed 3.
• Available temperature ranges are as follows:
Cooling/Drying:
19 - 30 °C, 66 °F - 86 °F
Heating:
17 - 28 °C, 63 °F - 82 °F
Automatic:
19 - 28 °C, 66 °F - 82 °F
• The display flashes either 8 °C - 39 °C, 46 °F - 102 °F to inform
you if the room temperature is lower or higher than the displayed
temperature.
6
) button 2 and select the
15 minutes (switches
from heating to cooling)
Set temperature +2°C, +4°F
Set temperature
Set temperature -2°C, -4°F
5.4. Fan speed setting
Press the Fan Speed button 5 as many times as necessary while the
system is running.
• Each press changes the force. The currently selected speed is
shown at 5.
• The change sequence, and the available settings, are as follows.
FAN SPEED
3-speed
Speed 1
+
Auto
Note:
The number of available fan speeds depends on the type of unit
connected. Note also that some units do not provide an "Auto" setting.
In the following cases, the actual fan speed generated by the unit will differ
from the speed shown the remote controller display.
1. While the display is showing "STAND BY" or "DEFROST".
2. When the temperature of the heat exchanger is low in the heat mode.
(e.g. immediately after heat operation starts)
3. In HEAT mode, when room temperature is higher than the temperature
setting.
4. When the unit is in DRY mode.
5.5. Airflow up/down direction setting
<To change the airflow up/down direction>
With the unit running, press the Airflow up/down button 6 as
necessary.
• Each press changes the direction. The current direction is shown at
6.
• The change sequence, and the available settings, are as follows.
Airflow
Swing
Wireless
remote-
controller
Swing
Auto
Wired
remote-
controller
* Note that during swing operation, the directional indication on the
screen does not change in sync with the directional vanes on the
unit.
* Some models do not support directional settings.
Note:
Available directions depend on the type of unit connected. Note also that
some units do not provide an "Auto" setting.
In the following cases, the actual air direction will differ from the direction
indicated on the remote controller display.
1. While the display is showing "STAND BY" or "DEFROST".
2. Immediately after starting heater mode (while the system is waiting for
the operation mode change to take effect).
3. In heat mode, when room temperature is higher than the temperature
setting.
<[Manual] To Change the Airflow's Left/Right Direction>
* The louver button 7 cannot be used.
Model PKA-A·KA(L)
• Stop the unit operation, hold the lever of the louver
airflow vanes, and adjust to the desired direction.
* Do not set to the inside direction when the unit is in
the cooling or drying mode because there is a risk
of condensation and water dripping.
Caution:
To prevent falls, maintain a stable footing when operating the unit.
Display
Speed 2
Speed 3
Auto
1
2
3
4
1
2
3
4
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pka-a·kal

Table of Contents