Dimplex LI 11ME Installation And Operating Instructions Manual

Dimplex LI 11ME Installation And Operating Instructions Manual

Air-to-water heat pump for indoor installation
Table of Contents

Advertisement

LI 11ME
Luft/Wasser-
Wärmepumpe für
Innenaufstellung
Bestell-Nr. / Order no. / N
Air-to-Water
Heat Pump for
Indoor Installation
o
de commande : 452160.66.22
Montage- und
Gebrauchsanweisung
Installation and
Operating Instructions
Instructions d'installation
et d'utilisation
Pompe à chaleur
air-eau pour
installation
intérieure
FD 8611

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LI 11ME and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dimplex LI 11ME

  • Page 1 LI 11ME Montage- und Gebrauchsanweisung Installation and Operating Instructions Instructions d’installation et d’utilisation Luft/Wasser- Air-to-Water Pompe à chaleur Wärmepumpe für Heat Pump for air-eau pour Innenaufstellung Indoor Installation installation intérieure Bestell-Nr. / Order no. / N de commande : 452160.66.22...
  • Page 2: Table Of Contents

    Maintenance / Cleaning ........................E-8 8.1 Maintenance ............................E-8 8.2 Cleaning the Heating System ......................... E-8 8.3 Cleaning the Air System ......................... E-8 Faults / Trouble-Shooting ......................E-8 10 Decommissioning/Disposal ......................E-8 11 Device Information ........................E-9 Anhang / Appendix / Annexes ......................A-I www.dimplex.de...
  • Page 3: Please Read Immediately

    Please Read 1.2 Legal Regulations and Immediately Directives The construction and design of the heat pump complies with all relevant EU directives, DIN/VDE regulations (see CE declaration 1.1 Important Information: of conformity). When connecting the heat pump to the power supply, the rele- ATTENTION! vant VDE, EN and IEC standards are to be fulfilled.
  • Page 4: Purpose Of The Heat Pump

    The evap- Liquifier orator is defrosted automatically by the heat pump as required. Expansion valve Steam may be emitted from the air outlet depending on the at- mospheric conditions. Compressor www.dimplex.de...
  • Page 5: Switch Box

    Transport 3.2 Switch Box The switch box is located in the heat pump. It can be swung out ATTENTION! after removing the lower front cover and loosening the fastening When transporting the heat pump, ensure that it is not tilted more than screw located in the upper right-hand corner.
  • Page 6: Set-Up

    There should be no contact with the external sheeting. Installed air ducts should be sound-isolated from the heat pump to prevent the transmission of solid-borne sound to the ducts. www.dimplex.de...
  • Page 7: Heating System Connection

    Antifreeze A method of manual drainage (see illustration) should be pro- vided for heat pumps which are exposed to frost. The antifreeze function of the heat pump controller is active whenever the con- troller and the heat circulating pump are ready for operation. If the heat pump is taken out of service or in the event of a power failure, the system has to be drained.
  • Page 8: Start-Up

    0 °C 1 °C 5 °C 6 °C 10 °C 11 °C 15 °C 10 K 16 °C 20 °C 11 K 21 °C 25 °C 12 K 26 °C 30 °C 13 K 31 °C 35 °C 14 K www.dimplex.de...
  • Page 9: Maintenance / Cleaning

    Maintenance / Cleaning 8.3 Cleaning the Air System Air ducts, evaporator, ventilator and condensate outflow should 8.1 Maintenance be cleaned of contamination (leaves, twigs, etc.) before the heat- ing period. Do this by opening the front of the heat pump. The To protect the paintwork, avoid leaning or putting objects on the bottom should be opened first followed by the top.
  • Page 10: Device Information

    11 Device Information Type and order code LI 11ME Design Degree of protection according to EN 60 529 for compact devices IP 21 and heating components Installation location Indoors Performance data Operating temperature limits: Heating water flow/return flow °C / °C Up to 58 / above 18 °C...
  • Page 11: Anhang / Appendix / Annexes

    4.2 Monoenergetische Anlage und Warmwasserbereitung / Mono energy system and domestic hot water preparation / Installation mono-énergétique et production d´eau chaude ..........A-IX 4.3 Bivalente Anlage / Bivalent system / Installation bivalente ..............A-X 4.4 Legende / Legend / Légende.........................A-XI Konformitätserklärung / Declaration of Conformity / Déclaration de conformité ....A-XII www.dimplex.de...
  • Page 12: Maßbilder / Dimension Drawings / Schémas Cotés

    1 Maßbilder / Dimension Drawings / Schémas cotés 1.1 Maßbild / Dimension drawing / Schéma coté A-II...
  • Page 13: Diagramme / Diagrams / Diagrammes

    2 Diagramme / Diagrams / Diagrammes 2.1 Kennlinien / Characteristic curves / Courbes caractéristiques www.dimplex.de A-III...
  • Page 14: Stromlaufpläne / Circuit Diagrams / Schémas Électriques

    3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung / Control / Commande A-IV...
  • Page 15: Last / Load / Charge

    3.2 Last / Load / Charge www.dimplex.de...
  • Page 16: Anschlussplan / Circuit Diagram / Schéma Électrique

    3.3 Anschlussplan / Circuit Diagram / Schéma électrique A-VI...
  • Page 17: Legende / Legend / Légende

    Pièces à fournir par le client - - - - - bauseits bei Bedarf anzuschließen To be connected by the customer as required à raccorder par le client au besoin ––––– werksseitig verdrahtet Wired ready for use câblé départ usine www.dimplex.de A-VII...
  • Page 18: Hydraulische Prinzipschemen / Hydraulic Plumbing Diagrams / Schémas Hydrauliques . A-Viii

    4 Hydraulische Prinzipschemen / Hydraulic Plumbing Diagrams / Schémas hydrauliques 4.1 Monoenergetische Anlage / Mono energy system / Installation mono- énergétique A-VIII...
  • Page 19: Monoenergetische Anlage Und Warmwasserbereitung / Mono Energy System And Domestic Hot Water Preparation / Installation Mono-Énergétique Et Production D´eau Chaude

    4.2 Monoenergetische Anlage und Warmwasserbereitung / Mono energy system and domestic hot water preparation / Installation mono- énergétique et production d´eau chaude www.dimplex.de A-IX...
  • Page 20: Bivalente Anlage / Bivalent System / Installation Bivalente

    4.3 Bivalente Anlage / Bivalent system / Installation bivalente...
  • Page 21: Legende / Legend / Légende

    Sonde d’eau chaude Vorlauffühler Flow sensor Sonde aller Elektroverteilung Electrical distribution system Distributeur courant électrique Kaltwasser Cold water Eau froide Mischer AUF Mixer OPEN Mélangeur OUVERT Mischer ZU Mixer CLOSED Mélangeur FERME Warmwasser Domestic hot water Eau chaude www.dimplex.de A-XI...
  • Page 22: Konformitätserklärung / Declaration Of Conformity / Déclaration De Conformité

    5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité A-XII...
  • Page 23 Glen Dimplex Deutschland GmbH Irrtümer und Änderungen vorbehalten. Geschäftsbereich Dimplex Subject to alterations and errors. Am Goldenen Feld 18 Sous réserve d’erreurs et modifications. D-95326 Kulmbach +49 (0) 9221 709 565 www.dimplex.de...

This manual is also suitable for:

Li 11teLi 16te

Table of Contents