External Control Device Setup - LG MU-42PZ90V Service Manual

Plasma monitor
Hide thumbs Also See for MU-42PZ90V:
Table of Contents

Advertisement

EXTERNAL CONTROL DEVICE SETUP

- Connect the RS-232C input jack to an external control device (such as a computer or an A/V control system)
and control the Monitor's functions externally.
- Connect the serial port of the control device to the RS-232C jack on the Monitor back panel.
- RS-232C connection cables are not supplied with the Monitor.
RS-232C Setup
RS-232C Setup
( )
( )
( )
( )
R
L
RS-232C INPUT
EXTERNAL SPEAKER
DVI INPUT
(CONTROL/SERVICE)
T
T
ype of Connector; D-Sub 9-Pin Male
ype of Connector; D-Sub 9-Pin Male
No.
Pin name
1
No connection
2
RXD (Receive data)
3
TXD (Transmit data)
4
DTR (DTE side ready)
5
GND
6
DSR (DCE side ready)
7
RTS (Ready to send)
8
CTS (Clear to send)
9
No Connection
RS-232C Configurations
RS-232C Configurations
7-Wire Configurations
(Standard RS-232C cable)
PC
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
R
L
AUDIO
EXPANDED
RGB INPUT
AUDIO INPUT
RGB OUTPUT
AUDIO INPUT
INPUT
PC
PDP
TXD
3
2
RXD
5
GND
DSR
6
4
DTR
8
CTS
RTS
7
D-Sub 9
- 8 -
Y
P
B
P
R
R
AUDIO
L
(MONO)
REMOTE
VIDEO
COMPONENT INPUT
S-VIDEO
AUDIO INPUT
AC INPUT
CONTROL
INPUT
3-Wire Configurations
(Not standard)
PC
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
1
5
9
6
PDP
TXD
3
RXD
2
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mu-42pz90xvMu-42pz90xc

Table of Contents