External Control Device Setup

- Connect the RS-232C input jack to an external control device (such as a computer or an A/V control system)
and control the Monitor's functions externally.
- Connect the serial port of the control device to the RS-232C jack on the Monitor back panel.
- RS-232C connection cables are not supplied with the Monitor.
T
T
ype of Connector; D-Sub 9-Pin Male
ype of Connector; D-Sub 9-Pin Male
No.
Pin name
1
No connection
2
RXD (Receive data)
3
TXD (Transmit data)
4
DTR (DTE side ready)
5
GND
6
DSR (DCE side ready)
7
RTS (Ready to send)
8
CTS (Clear to send)
9
No Connection
RS-232C Configurations
RS-232C Configurations
7-Wire Configuration
(Standard RS-232C cable)
PC
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
Set ID
Set ID
- Use this function to specify a monitor ID number.
- Refer to 'Real Data Mapping 1'. See page 27.
1. Press the MENU button and then use the
2. Press the
G
button and then use
3. Press the
G
button and then use
monitor ID number.
• The adjustment range of SET ID is 1 ~ 99.
24
PDP
TXD
3
2
RXD
GND
5
6
DSR
DTR
4
8
CTS
RTS
7
D-Sub 9
button to select the SPECIAL menu.
D / E
button to select SET ID.
D / E
button to adjust SET ID to choose the desired
F / G
3-Wire Configuration
(Not standard)
PC
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
SPECIAL
LANGUAGE
OSD ROTATE
ORBITER
WHITE WASH
COLOR TEMP.
SET ID
1
5
9
6
PDP
TXD
3
RXD
2
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
G
1