External Control Device Setup - LG MU-42PM20 Owner's Manual

Hide thumbs Also See for MU-42PM20:
Table of Contents

Advertisement

External Control Device Setup

External Control Device Setup
- Connect the RS-232C input jack to an external control device (such as a computer or an A/V control system)
and control the Monitor's functions externally.
- Connect the serial port of the control device to the RS-232C jack on the Monitor back panel.
- RS-232C connection cables are not supplied with the Monitor.
RS-232C Setup
RS-232C Setup
REMOTE
RS-232C INPUT
DVI INPUT
AUDIO INPUT
CONTROL
(CONTROL/SERVICE)
T
ype of Connector; D-Sub 9-Pin Male
T
ype of Connector; D-Sub 9-Pin Male
No.
Pin name
1
No connection
2
RXD (Receive data)
3
TXD (Transmit data)
4
DTR (DTE side ready)
5
GND
6
DSR (DCE side ready)
7
RTS (Ready to send)
8
CTS (Clear to send)
9
No Connection
RS-232C Configurations
RS-232C Configurations
7-Wire Configurations
(Standard RS-232C cable)
PC
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
All manuals and user guides at all-guides.com
COMPONENT
INPUT 2
COMPONENT
INPUT 1
R
RGB INPUT
VIDEO
AUDIO
PC
PDP
3
TXD
2
RXD
GND
5
DSR
6
DTR
4
8
CTS
7
RTS
D-Sub 9
External Control Device Setup
MONITOR
OUTPUT
A/V
Antenna
INPUT 1
S-VIDEO
L
R
L/MONO
AUDIO
VIDEO
3-Wire Configurations
(Not standard)
PC
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
AC INPUT
1
5
9
6
PDP
TXD
3
RXD
2
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
Owner's Manual 29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mu-42pm12xMu-42pm11Mu-50pm10Mu-50pm11Mu-50pm20

Table of Contents