The projector is fitted with a power supply cable and two XLR 5 Poles connectors for DMX IN and OUT signal (Fig.1)
Fig. 1
Any modification to this luminaries, without authorization, is forbidden.
This lantern must be powered according to the voltage and frequency showed on its label (100/240V 50/60Hz). Connect the power
cable to the socket. We suggest to connect each projector to its own switch so that they can be individually switched on with a remote
control.
To remote control the projectors is required the use of a DMX512 control desk.
For the connection of signal use cable EIA rs-485 type: two core screened, 120Ω characteristic impedance, 22-24 AWG, low capacity, 1
XLR 5 poles MALE connector and 1 XLR 5 poles FEMALE connector.
To form a DMX chain, connect the DMX control desk to the first projector's DMX IN, then from its DMX OUT to the DMX IN of the
second projector and so on.
For a correct functioning of the DMX signal, it is necessari to put a terminal into the DMX OUT of the last projector. This terminal is
made of 1 XLR MALE connector with a 120Ω resistance welded between PIN 2 and PIN 3.
Digital display and functioning options
Using the digital display, it is possible to change the functioning options, drive the projector in automatic mode with presets or programs
and with Master/Slave functions, display projector information and reset settings to default.
After 30 seconds without working, the display will turn off.
The low right dot is a dmx signal indicator:
Fixed ON : dmx signal is linked
-
Slow flashing: dmx signal is not linked
-
Quik flashing: dmx signal is linked but control channels are not enough
-
Addressing of the projector
To control many Fusion Color individually, it is necessary to assign to each one a different DMX address , setting the starting channel
taking into consideration that one Fusion Color books 7 channels (3 or 4 or 6 or 7 channels depending on the functioning mode set).
For example, if we have 6 projectors, it will be necessary to set them on the channels 1, 8, 15, 22, 29, 36.
To set the DMX channel use buttons 'UP' or 'DOWN' until you can see 'Address' on the display , then press 'ENTER'. Change the DMX
address using the 'UP' 'DOWN' keys and then press 'ENTER' to confirm.
Cod. 7136694005 – Cod. 7136494005 (IP44) v 1.1 IT/EN
DMX IN
DMX OUT
Power supply connection:
Supply: 100/240V 50/60Hz
Fuse: T 3.15 A 250 V
DMX connector:
1: GND (screen)
2: data –
3: data +
4: NC
5: NC