  • Page 1 Spot 575 TM3 Spot 575 TM3 User Manual Rel 1.0...
  • Page 2: Spot 575 Tm3 Arc

    Teclumen Teclumen si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di design a ciascun proprio prodotto. Teclumen non assume alcuna responsabilità sull’uso o sull’applicazione dei prodotti o dei circuiti descritti.
  • Page 3: Table Of Contents

    Spot 575 TM3 ARC 1200 INDEX: 1- TECHNICAL FEATURES 2- IMPORTANT SAFETY INFORMATION 2.1 Fire prevention 2.2 Prevention of electric shock 2.3 Protection against ultraviolet radiation 2.4 Safety 2.5 Level of protection against the penetration of solid and liquid matter 3- MOUNTING THE LAMP 3.1 Lamp alignment...
  • Page 4 Spot 575 TM3 ARC 1200 1- TECHNICAL FEATURES The Spot 575 TM3 is fitted with a Philips MSR 575/2 discharge lamp (GX9,5 lampholder base), with a colour temperature of 7,200 °K and a luminous flux of 49,000 Lumens. Duration is 750 hours, with replacement recommended before 1000 hours Other recommended lamps: Philips 575 MSD (6.000K°-49.000 Lumens-3.000 hours)
  • Page 5: Important Safety Information

    -The level of technology present in the Spot 575 TMrequires the assistance of specialised personnel for all servicing. Please refer to an authorised Teclumen service centre. -A good earth connection is essential for proper functioning of the projector .
  • Page 6: Mounting The Lamp

    3)Insert the lamp (photo 3). The lamp used on Spot 575 TM3 is made in quartz glass and should be handled with care. Always follow the instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided in the lamp's packaging.
  • Page 7: Voltage And Frequency

    Spot 575 TM3 4- VOLTAGE AND FREQUENCY The Spot 575 TMwith electronic ballast can operate at 90-245 VOLT 50 or 60 Hz. The Spot 575 TMwith electromagnetic ballast can operate at 230 V 50-60 Hz(Standard) On request: 100 V 50-60 Hz /120 V 60 HZ / 208 V 60 Hz 5- INSTALLATION Spot 575 TMmay be either floor or ceiling mounted.
  • Page 8: Mains Connection

    Spot 575 TM3 5.3- Movement The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any obstructions in the path of the projector's movement. 270° 540° 5.4- Risk of fire Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended distance from flammable material is 1 MT.
  • Page 9 120 ohm PIN 2 The standard configuration of the Spot 575 TM3 is with XLR 5 pins connection. To convert to an XLR 3 pins configuration proceed as follows: 1) Remove the 2 screws fixing the display cover panel to the unit (photo 1).
  • Page 10 Spot 575 TM3 can be used in two different modes: 16 or 20 DMX (default) channels. If you want to use the Spot 575 TM3 in 16 channels mode, select the 16 CH mode from the MODE menu and set the following addresses on the mixer:...
  • Page 11: Display Functions

    ENTER DISPLAY FUNCTIONS The Spot 575 TM3 display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the Teclumen setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it.
  • Page 12 Spot 575 TM3 8- DISPLAY FUNCTIONS GOBO SHAKE MENU Up-Down ENTER Up-Down TEST MODE EFFECTS Full test and single function test. EFFECTS ROT. TILT COLOR DIMMER SHUTTER FOCUS ZOOM GOBO FROST GOBO ROT. ENTER ENTER MENU Up-Down Up-Down ENTER Up-Down...
  • Page 13 Spot 575 TM3 8- DISPLAY FUNCTIONS ON / OFF VIA DMX (default) Up-Down MENU Up-Down ENTER ENTER LAMP FORCED ON Lamp always ON-always OFF ENTER Or lamp ON-OFF selectable via DMX FORCED OFF ENTER ADJUST To adjust the lamp with no mixer connected.
  • Page 14: Automatic Mode

    (16CH DMX) and setting the DMX address to A001. 9.2-Rec Mode It is possible to program your own game on the Spot 575 TM3 that will then run in AUTO mode (GAME P). Each unit can have its own programmed game.
  • Page 15: Pan & Tilt Speed

    10- PAN & TILT SPEED (SPEE) (default: 2) You can set the PAN and TILT motors at high speed on your Spot 575 TM3. Press menu until you see SPEE. Press ENTER and select a speed with UP-DOWN (there are 4 speeds). Confirm by pressing ENTER.
  • Page 16: Hidden Menu

    -Connect the projector to the DMX controller (DMX SIGNAL MUST BE CORRECTLY RECEIVED) Reset the Spot 575 TM3 (reset from the MENU, not from the DMX controller!). While reset is running, press the MENU and ENTER keys at the same time.
  • Page 17: Opening The Projector Housing

    Photo 1 15- REPLACING GOBOS Spot 575 TM3 uses a mechanical system which allows the fixture's gobos to be removed without the use of special tools. Replacement gobos should be made of either heat resistant glass or metal. An ever-increasing range of gobos is available from your Teclumen sales network.
  • Page 18: Periodic Cleaning

    Fuse replacement Locate the fuse, which protects the lamp and electronics, in the base of the Spot 575 TM3. Using a multimeter, test the condition of the fuse, replacing it with one of equivalent type if necessary.
  • Page 19: Dmx Protocol

    Spot 575 TM3 ARC 1200 18- DMX PROTOCOL 16 CHANNELS MODE PAN msb 540° PAN lsb TILT msb 270° TILT lsb SPEED MOVEMENT DIMMER SHUTTER COLOUR COLOUR PROPORTIONAL (Priority in color channel) GOBO GOBO ROTATION PRISM/PRISM ROTATION FOCUS ZOOM FROST (Priority on Zoom channel)
  • Page 20 Spot 575 TM3 ARC 1200 Black-out 9-255 Proportional dimmer DMX CHANNEL SHUTTER Parameter: Move DMX range Mid point range Mode Option Function Value DMX value (degrees) Black-out 10-23 StrobE random speed 24-37 Strobe speed 1 min. 38-51 Strobe speed 2...
  • Page 21 Spot 575 TM3 ARC 1200 165-175 Bicolour 8/9 176-186 Colour9 187-197 Bicolour 9/1 198-200 Right rotation speed 1 min. 201-203 Right rotation speed 2 204-206 Right rotation speed 3 207-209 Right rotation speed 4 210-212 Right rotation speed 5 213-215...
  • Page 22 Spot 575 TM3 ARC 1200 244-249 Speed rotation 7 250-255 Speed rotation 8 max. DMX CHANNEL ROTO GOBO Parameter: Move DMX range Mid point range Mode Option Function Value DMX value (degrees) 0-127 Proportional from 0° to 360° 128-180 Left rotation...
  • Page 23 Spot 575 TM3 ARC 1200 DMX CHANNEL RESET Parameter: Move DMX range Mid point Mode Option Function range Value DMX value (degrees) 0-29 No effect Lamp OFF (actived after 3 30-85 seconds) 86 - 170 Internal motor Reset 171-235 Total Reset...
  • Page 24 Spot 575 TM3 20 CHANNELS MODE (DEFAULT) PAN msb 540° PAN lsb TILT msb 270° TILT lsb P/T SPEED MOVEMENT DIMMER SHUTTER COLOUR COLOUR MODE GOBO GOBO MODE GOBO ROTATION-INDEX GOBO ROTATION-INDEX FINE GOBO SHAKE PRISM PRISM ROTATION FOCUS ZOOM...
  • Page 25 Spot 575 TM3 DMX CHANNEL DIMMER Parameter: Move DMX range Mid point Mode Option Function range Value DMX value (degrees) Black-out 9-255 Linear dimmer DMX CHANNEL SHUTTER Parameter: Move DMX range Mid point Mode Option Function range Value DMX value...
  • Page 26 Spot 575 TM3 DMX CHANNEL COLOUR Parameter: Move DMX range Mid point range Mode Option Function Value DMX value (degrees) IF CHANNEL 9 = HALF COLOUR (Dmx range value 64 - 127) 0-25 No Colour 26-51 Bicolour ½ Bicolour 2/3...
  • Page 27 Spot 575 TM3 DMX CHANNEL GOBO Parameter: Move DMX range Mid point range Mode Option Function Value DMX value (degrees) Rotation speed 2 214-219 220-225 Rotation speed 3 Rotation speed 4 226-231 232-237 Rotation speed 5 238-243 Rotation speed 6...
  • Page 28 Spot 575 TM3 DMX CHANNEL GOBO SHAKE Parameter: Move DMX range Mid point range Mode Option Function Value DMX value (degrees) Gobo Shake R-L Speed 4 49-61 Gobo Shake R-L Speed 5 62-74 Gobo Shake R-L Speed 6 75-87 Gobo Shake R-L Speed 7...
  • Page 29 Spot 575 TM3 DMX CHANNEL ZOOM Parameter: Move DMX range Mid point range Mode Option Function Value DMX value (degrees) 11° 0-84 15° 85-170 18° 171-255 FROST DMX CHANNEL Parameter: Move DMX range Mid point range Mode Option Function Value...
  • Page 30: Gobo Wheel

    Spot 575 TM3 ARC 1200 19- GOBO WHEEL GOBO 1 DICHROIC GOBO 2 DICHROIC GOBO 3 DICHROIC 0516G029.02 0516G029 0516G029.01 GOBO 4 METAL GOBO 5 METAL GOBO 6 METAL GOBO 7 METAL 0516G030.01 0516G030.02 0516G030.03 0516G030.04...
  • Page 31: Colour Wheel

    Spot 575 TM3 ARC 1200 20- COLOUR WHEEL COL1 COL2 COL3 COL4 0507C045.D01 0507C042.D01 0507C043.D01 0507C051.D01 CYAN SW 530 GREEN WB5055 LAVANDER SL0064 ORANGE LW590 COL5 COL6 COL7 COL8 0507C047.D01 0507C052.D01 0507C041.D01 0507C049.D01 PINK SL4761 DARK BLUE SW490 YELLOW LW 515...
  • Page 32: Motors Control Card

    Spot 575 TM3 21- MOTORS CONTROL CARD Display 8 MOTORS PCB Gobo (BLACK) Magnetic Sensors ORANGE Line 1 Brown BROWN Line 2 Orange Focus (DARK GREEN) Strobe J3 FROM (YELLOW) J8 PAN & TILT Prism (PINK) J5 FROM Zoom J10 PAN & TILT...
  • Page 33: Pan & Tilt Card

    Spot 575 TM3 ARC 1200 22-PAN & TILT CARD TILT 30 VDC (WHITE) (BROWN) (BLACK) (RED) (WHITE) ENCODER PAN (RED) ENCODER TILT (ORANGE) FROM CN5 LAMP ON-OFF FROM J5 FROM J3 DMX IMPUT 8 MOTORS 8 MOTORS (WHITE) (LIGHT GREEN)
  • Page 34 Spot 575 TM3 ARC 1200 26- WIRING DIAGRAMS 125VA...
  • Page 35 Spot 575 TM3 NOTES...
  • Page 36 Teclumen. Teclumen reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. Teclumen assumes no responsibility for the use or application of the products or circuits described herein.