PRIMERGY TX200 S2
RAID Controller / SCSI Controller
Restrictions and Notes of RAID Controller Card
Here are the restrictions and notes of RAID Controller Cards. Please be sure to use products
along with these conditions as follows;
[PG-140D1]
1. One Controller Card can be mounted in a server
2. Used only for internal HDD connection. On board SCSI Controller is used for the connection with internal HDD
3. For RAID0/1/5, When one logical drive exists in physical pack, physical pack expansion capability is available.
(only Windows Server
2003/Windows® 2000 supported)
TM
4. In case of using RAID controller card under Linux environment, Windows terminal is required separately to set and observe RAID
[PG-142E3]
1. For RAID0/1/5, When one logical drive exists in physical pack, physical pack expansion capability is available.
(only Windows Server
2003/Windows® 2000 supported)
TM
2. In case of using RAID controller card under Linux environment, Windows terminal is required separately to set and observe RAID
[On board SCSI Controller (RX300 S2/RX600 S2)]
1. Used only for internal HDD connection. On board SCSI Controller is used for the connection with internal HDD
2. For RAID0/1/5, When one logical drive exists in physical pack, physical pack expansion capability is available.
(only Windows Server
2003/Windows® 2000 supported)
TM
3. In case of using RAID controller card under Linux environment, Windows terminal is required separately to set and observe RAID
[On board SCSI Controller (RX100 S3/RX200 S2)]
1. Used only for internal HDD connection. On board SCSI Controller is used for the connection with internal HDD
2. In case that On board SCSI Controller is used for RAID configuration, only 2 HDDs of same capacity and same rpm can be connected.
3. In case of using RAID controller card under Linux environment, Windows terminal is required separately to set and observe RAID
Combination matrix of RAID Controller
TX200 S2
Standard Cage
When Internal HDD Unit Bay
Conversion kit (PG-BC102) is applied.
TX200FT S2
RX100 S3
RX200 S2
RX300 S2
RX600 S2
RAID Controller OS Compatibility List
Windows Server
2003, Standard Edition
TM
Windows Server
2003, Enterprise Edition
TM
Windows Server
2003, Standard x64 Edition
TM
Windows Server
2003, Enterprise x64 Edition
TM
Windows® 2000 Server
Windows® 2000 Advanced Server
Windows® Small Business Server 2003
Red Hat Enterprise Linux ES (v.3 for x86)
Red Hat Enterprise Linux ES (v.4 for x86)
Red Hat Enterprise Linux AS (v.3 for x86)
Red Hat Enterprise Linux AS (v.4 for x86)
Red Hat Enterprise Linux ES (v.4 for EM64T)
Red Hat Enterprise Linux AS (v.4 for EM64T)
Notes of SCSI Controller
[PG-128/PG-130L]
1. When the external SCSI controller and the internal SCSI controller are connected simultaneously,
SCSI Controller must be separated.
[PG-129B]
1. This card can be connected only to the the internal SCSI controller.
PG-140D1
(Ultra320 SCSI, 0ch)
Internal HDD
Internal HDD
o
o
o
o
x
o
x
x
x
x
x
x
x
x
RAID Controller
PG-140D1
PG-142E3
o
o
o
o
o
o
o
o
o
o
o
o
o
x
o
o
o
o
o
o
o
o
o
o
x
o
PG-142E3
(Ultra320 SCSI, 2ch, BBU)
Internal HDD
External HDD
External HDD
o
o
x
x
o
o
o
* o: Supported
x: Not Supported
+
o
x
x
x
x
x
* o: Supported
x
x: Not Supported

Advertisement