No.
ITEM
1
LASER POWER
Note:
Type 4 disc : SONY YEDS-18 Test Disc or equivalent.(KTD-0 )
(a) Laser power
Pickup

ADJUSTMENT

INPUT
OUTPUT
SETTINGS
SETTINGS
Apply the sensor section
of optical power meter
on the pickup lens.
0.08~0.15 mW
Optical power meter
RXD-302/A31
PLAYER
ALIGNMENT
SETTINGS
POINTS
Press the
PLAY/PAUSE key.
ALIGN
FIG.
FOR
On the power from
0.08 to 0.15 mW,
when the diffraction
grating is correctly
(a)
aligned with the RF
level of 0.6 Vp-p or
more.