Controllers Responders Controller-Only Responder-Only Grouping Devices Use Cross Linking Linking to the INSTEON Hub Linking with a Single-Button Controller Linking with a Multi-Button Controller Multi-Linking or Making a Scene Unlinking from a Single-Button Controller Unlinking from a Multi-Button Controller Multi-Unlinking or Removing a Scene...
INSTEON On/Off Module Device Overview Buttons Status LED Tap to turn on For dimmable responders: Double-tap to turn on instantly Press and hold to brighten Tap to turn off For dimmable responders: Double-tap to turn off instantly Press and hold to dim...
INSTEON Links INSTEON Links INSTEON devices can stand alone and function as a local switch or INSTEON devices can stand alone and function as a local switch or dimmer, but their real power comes when they are connected together to dimmer, but their real power comes when they are connected together to form a control system.
Switch B cannot turn Switch A on or off. 75% brightness. Controllers Responders INSTEON devices that can turn other devices INSTEON devices that receive the command of a on or off are called controllers. controller are called responders. ® Neutral ®...
Understanding Linking Controller-Only Responder-Only Some devices like sensors can only control Some devices cannot control other devices; other devices. these devices only receive INSTEON commands. ® Motion Sensor Dimmer Switch LED Bulb Dimmer Switch The Motion Sensor will turn on the Switch...
Linking to the INSTEON Hub Tap the Add button. From Rooms, navigate to All Devices. Rooms All Devices All Devices Check-In Favorites Back Door Bathroom Bedroom Bathroom Bedroom Hallway Font Door Garage Door Garage Light Kitchen Living Room Outside Motion Sensor Outside Lights 72º...
Linking with a Single-Button Controller Make sure the On/Off Module is On your INSTEON controller, press On and then press and hold the and hold the set button until the On/Off Module’s set button until device beeps. the device double-beeps.
Linking with a Multi-Button Controller Make sure the On/Off Module is On your INSTEON controller, tap On and then press and hold the the desired control button and On/Off Module’s set button until then press and hold the set button until the device beeps.
Multi-Linking or Making a Scene Adjust your scene members to On your INSTEON controller, press their desired state: on, off, or and hold the set button until the device beeps, then tap the set brightness level if dimming. button. Lamp 1...
Unlinking from a Single-Button Controller Press and hold the set button On your INSTEON controller, press again until the device beeps. and hold the set button until the device beeps. Press and hold the On/Off Module’s set button until the device double-beeps.
Unlinking from a Multi-Button Controller On your INSTEON controller, tap Press and hold the set button the desired control button and again until the device beeps. then press and hold the set button until the device beeps. Press and hold the On/Off Module’s set button until the...
Press and hold the set button again, then tap the set button. ® Tap the set button on your INSTEON controller to exit Multi- Unlinking mode. ® ® ® Your INSTEON controller will no longer control your INSTEON responders.
Local Programming Local Programming Use the local programming to set local on-level, ramp rates and even Use local programming to set local on-level, ramp rates and even perform perform a factory reset. a factory reset.
INSTEON device or four minutes have elapsed without linking. Multi- Allows the removal of multiple links from the INSTEON module. The device will stay in unlinking mode for Unlinking 4 minutes or until the device’s set button is tapped.
Software-Only Features Software-Only Features Most INSTEON devices contain features that can only be enabled, Most INSTEON devices contain features that can only be enabled, disabled or modified using INSTEON control software such as HouseLinc disabled or modified using INSTEON control software such as HouseLinc and an INSTEON PowerLine Modem or the INSTEON Hub.
Error Blink The On/Off Module LED will blink if it detects The On/Off Module LED will blink red once if INSTEON communication. By default, this one or more responders do not acknowledge feature is disabled. a message and will blink green once if all responders successfully acknowledge a message.
Appendix Appendix Everything else you might need to know about your INSTEON product. Everything else you might need to know about your INSTEON product.
Page 21
A special mode that allows more than one link to be either created or removed / Unlinking simultaneously, without laborious set button presses. When in linking or unlinking mode, an INSTEON device will continue to link to other devices until the set button is tapped or four minutes have elapsed, whichever occurs first. Factory A process that erases all stored links and reconfigures the device to factory defaults.
Brand: INSTEON FCC ID SBP26352 Industry Canada 5202A-26352 Manufacturer Product No.: 2635-222 Patent No.: Protected under US and Foreign Patents (see www.insteon.com/ patents) UPC: 813922013368 Warranty: 2 years, limited Operation Audio Alert Beeper, can be disabled through software Operation Modes...
Page 23
Maximum Scene Memberships Multi-Link Support Multi-Unlink Support RF Beacon Radio Frequency 915.0 MHz Radio Frequency Range 150 feet Scene Commands Supported as Controller Fast-On Fast-Off Begin Brighten Begin Dim End Brighten End Dim Scene Commands Supported as Responder Fast-On Fast-Off Beep Software Configurable Mechanical...
Page 24
Electrical Controlled Outlet Yes, grounded. NEMA 5-15 type Hardwired Remote Control Load Types General Appliances 15A Max Resistive 15A Max Incandescent 1,800W Max Motors 1HP Max Ballasts 10A Max Maximum Load 1,800 Watts (15 Amps) Minimum Load None Pass-through Outlet Power Consumption <0.75 Watts Supply Voltage...
• Your On/Off Module may be too far from another INSTEON device to receive a signal. Try locating the On/ Off Module closer to another INSTEON device and if the issue is resolved, install a Range Extender or other Dual-Band INSTEON device between the intended location of your On/Off Module and the next nearest INSTEON device.
Page 26
Troubleshooting The connected appliance turned on by itself There must be a device in your INSTEON network that is unexpectedly linked to the On/Off Module Try this: • Use software to examine the On/Off Module’s links. If you can identify the stray controller, remove the link.
To minimize heat buildup, ensure the area surrounding this product is as clear of clutter as possible. • Each INSTEON product is assigned a unique INSTEON I.D., which is printed on the product’s label. • To reduce the risk of overheating and possible damage to other equipment, do not use this product to control loads in excess of the specified maximum(s) or, install in locations with electricity specifications which are outside of the product’s specifications.
Need help?
Do you have a question about the 2635-222 and is the answer not in the manual?
Questions and answers