GE RGA620 Owner's Manual And Installation Instructions page 28

20" and 24" compact gas ranges
Table of Contents

Advertisement

Installation of the range.
Read these instructions completely and carefully.
Converting the Range for Use with LP (Propane) Gas (if necessary)
Skip to Step 4 if conversion is not necessary.
This range leaves the factory set for use with natural
gas. When converting to LP gas, keep these
instructions in case you need to convert back to
natural gas.
WARNING:
made by a qualified installer or gas supplier in
accordance with the manufacturer's instructions
and all codes and requirements of the authority
having jurisdiction. Failure to follow instructions
could result in serious injury or property damage.
The qualified agency performing this work
assumes responsibility for the conversion.
Burner Specifications:
Top Burner
Natural Gas
LP (Propane)
Natural Gas spud is
marked with an "N"
Tools Required:
• Adjustable wrench
• 1/2" open-end wrench
• Phillips-head screwdriver
• Flat-bladed screwdriver (blade width
approximately 3/32" across)
• 5/16" nutdriver or small adjustable wrench
28
This conversion must be
Orifice Drill Size Marking
#53 (.0590 dia.)
N
#66 (.0330 dia.)
L
LP Gas spud is marked
with an "L"
Prepare Range for Conversion:
1. Turn off the gas supply to the range.
2. Turn off electrical power to the range.
If the range has not yet been connected to the gas supply,
or if a flexible connection was made, the range may be
pulled out from the wall to make the conversion easier.
CAUTION: If the gas supply to range is disconnected
for any reason, see the installation instructions for
proper connection and safety precautions.
Convert the Pressure Regulator:
WARNING:
Do not remove the pressure
regulator from the range.
1. Lift the cooktop, prop it open and locate the
pressure regulator at the left rear of the range.
Gas flow
into range
Lever shown closed.
2. Use a large, flat-bladed screwdriver or a coin to
remove the cap from the pressure regulator.
3. Turn the cap over and hook it into the slots.
The type of gas to be used should now be
visible in the center of the cap.
Natural gas cap
(marked with "NAT")
Gas flow
into range
Lever shown closed.
Pull to open.
Oven only shut-off.
Pull to open.
Oven only shut-off.
LP gas cap
(marked with "LP")