Matching Connectors And Cables; Internal Switches; Board (Bkam-101); Sdi-43 Board (Bkam-103) - Sony BKAM-103 Installation Manual

Audio monitor speaker system
Table of Contents

Advertisement

1-6. Matching Connectors and Cables

When connecting cables to various connectors on the rear
panel at the time of installing or servicing, connect the
following connectors/cables or their equivalents.
Connector
Matching Connector/cable
Panel indication
Connector/Cable
REMOTE
D-sub 25-pin, male
AUDIO IN 1
XLR 3-pin, male
XLR 3-pin, female
AUDIO IN 2
XLR 3-pin, male
XLR 3-pin, female
DIGITAL AUDIO IN
XLR 3-pin, female
BNC 75 Z, male
5C-2V cable (*3)
BNC 75 Z, male
SDI IN
SDI OUT
5C-2V cable (*3)
(*1) : ITT Cannon XLR-3-12C or equivalent
(*2) : ITT Cannon XLR-3-11C or equivalent
(*3) : 5C-2V coaxial cable (max. 200 m)
It is recommended to use the 5C-2V coaxial cable made by Fujikura
America Inc./Fujikura Europe Ltd. (FEL) or equivalent.

1-7. Internal Switches

1-7-1. AL-42 Board (BKAM-101)
S2
S2: CH-1 input level select switch
To select the input level of CH-1.
Factory setting : +4 dB
S22: CH-2 input level select switch
To select the input level of CH-2.
Factory setting : +4 dB
AMS-100
Sony Part No.
1-566-356-11
1-508-084-00 (*1)
1-508-083-00 (*2)
1-508-084-00 (*1)
1-508-083-00 (*2)
1-508-083-00 (*2)
1-560-370-12
1-560-370-12
CN101
S22

1-7-2. SDI-43 Board (BKAM-103)

S101
S102
S101 : Free-run adjustment select switch for the
serial decoder
Used during free-run adjustment of the serial decoder:
OFF :
Normal operation
ON :
For free-run adjustment
Factory setting : OFF
S102 : Video system select switch
To select the video system (525/625).
(Effective for 4:2:2 component serial video signal mode)
525 :
For a 525 video system
625 :
For a 625 video system
Factory setting : 525
S103 : Mode select switch
ON
(
Indicates the switch lever position.)
1
2
3
4
S103-1 :
D1/D2 system selector
To select the video system used:
OFF (D1) : 4:2:2 component serial video signal
ON (D2) : 4fsc composite serial video signal
S103-2, -3, -4 : For factory-adjustment use only.
n
Do not change the factory presetting of
these switches.
Factory setting : all OFF
1-6. Matching Connectors and Cables
1-7. Internal Switches
CN101
S103
1-5(E)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bkam-101Bkam-102Ams-100

Table of Contents