Summary of Contents for Extron electronics HSA 200S
Page 1
User’s Manual HSA 200S & HSA 200SE HSA 200C & HSA 200CE HSA 222S & HSA 222C Hideaway Surface Access Products ® Extron USA - West Extron USA - East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East Headquarters 68-695-01 Rev.
Page 2
Precautions Safety Instructions • English Warning Power sources • This equipment should be operated only from the power source This symbol is intended to alert the user of important indicated on the product. This equipment is intended to be used with a main power operating and maintenance (servicing) instructions in Extron’s Warranty system with a grounded (neutral) conductor.
Page 3
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Underside Features and Cabling Connections ..2-8 All HSA 200 models only ............2-9 HSA 200C and HSA 200S (no Extender board) only .... 2-9 All HSA 200 and HSA 222 models ........2-10 HSA 200CE and HSA 200SE (Extender board) only .... 2-11 ..........
Table of Contents, cont’d Appendix A • Reference Information ......A-1 HSA 200/222 Series Surface Access Products Specifications ................. A-2 HSA Part Numbers ..............A-7 Included Parts ................. A-8 Routing Templates ............... A-8 Accessories ................A-8 Top Plate Dimensions ............A-8 Appendix B •...
For the HSA 200 model, the computer video signal is routed to 5 BNC connectors on pigtails. On HSA 200S and HSA 200C units, the audio signal Figure 1-1 — HSA 200C hideaway enclosure is sent to a 3-pole, 3.5 mm captive screw connector on a pigtail.
Introduction The installed enclosures fit nearly flush within a table or podium Features top (figure 1-4), storing the connectors out of the way and out of sight. To access the connectors, the user presses down on the All models top of the enclosure, releasing a mechanical latch. A gas lift tips •...
Introduction HSA 200/222 Series Surface Access Products Chapter Two Installation Installation Overview Preparing the Routing Template Preparing the Table and Mounting the Enclosure Underside Features and Cabling Connections Front Panel Connectors Pre-installation Testing and Troubleshooting (HSA 200CE and HSA 200SE Models Only) HSA 200/222 Series •...
Installation Installation Overview Preparing the Routing Template Install and set up the HSA surface access enclosures as follows: Extron offers a metal template for each HSA model. Appendix A lists the HSA 200 and HSA 222 template part If you have an unprepared mounting template, prepare numbers.
Installation, cont’d Preparing the Table and Mounting the Enclosure The preferred and recommended method for preparing the table is to use the appropriate Extron routing template and a router. See the part numbers for the templates in appendix A, “Reference Information”. For an HSA 200C, HSA 200CE, or HSA 222C unit (US version only), another preferred method is to use a 6"...
Installation, cont’d Preparing the table with a hole saw (HSA 200C, Remove the plastic strips that protect the corners of the enclosure. If a sticky residue remains, remove it with an HSA 200CE, or HSA 222C—US version only) appropriate metal cleaning product. Locate the desired mounting location on the tabletop or Do not use isopropyl alcohol or other solvents to clean CAUTION...
RGBHV video output — Connect the BNC cable from the projector, plasma screen, or other display device to these female BNC connectors. HSA 200C and HSA 200S (no Extender board) — The output from these connectors is an unbuffered pass-through from the front panel VGA input.
Installation, cont’d All HSA 200 and HSA 222 models Latch locking screws — These screws secure the latching mechanism to the enclosure. They must be loosened in order to Screw clamp bracket/screw clamp — These two brackets/ adjust the top surface (see “Adjusting the Top Panel” in clamps hold the enclosure firmly in place in the mounting hole.
Installation, cont’d Do not tin the stripped power supply leads. Tinned Power connector wiring wires are not as secure in the captive screw terminals See figure 2-10. Plug the input connector of the included and could pull out. 100-240 VAC, 50/60Hz, 12 VDC power supply into the AC power outlet on the underside of the enclosure ( The two power cord wires must be kept separate figure 2-5).
Page 15
Installation, cont’d The Universal AC outlet is fully compatible with Europlug, British, Indian, Danish, and Italian plug types. See the universal AC outlet guide on the Extron Web site, www.extron.com, for compatibility details on all plug types. Front View Computer video input (HSA 200 models only) — Plug the VGA-UXGA output from a computer into this 15-pin HD female connector.
Installation, cont’d Pre-installation Testing and Troubleshooting HSA 200/222 Series Surface Access Products (HSA 200CE and HSA 200SE Models Only) Before installing an HSA 200 with an Extender line driver into furniture, test the system to make sure that the connections and settings are correct.
Maintenance and Modifications The most probable corrective maintenance procedures for your The surfaces of the HSA enclosure have screws and other HSA 200 or HSA 222 are leveling the top surface and replacing protrusions that could damage fine furniture. Do not the gas lifts.
Page 18
Maintenance and Modifications, cont’d (HSA 222 models only) Remove the four Phillips head (HSA 222 models only) Disconnect both RJ-45 connectors screws from the front access panel (figure 3-1). Retain the from the underside of the enclosure by simultaneously screws. Lift the panel away from the enclosure. performing steps 3a and 3b: With a Tweeker in one hand, reach through the small access hole in the front of the enclosure (figure 3-2)
Page 19
Maintenance and Modifications, cont’d Remove the four 1/16" hex head screws on the right and Snap the internal RJ-45 connector onto the back of the front left sides of the front panel (figure 3-3). Retain the screws. panel enclosure bezel plug-in. Lift the panel away from the enclosure.
Maintenance and Modifications, cont’d Replacing the Gas Lift Slide the gas lift mounting plate toward the center of the enclosure, releasing the mounting plate (figure 3-5). The gas lift that raises the HSA surface is rated for 100,000 Turn the gas lift mounting plate counterclockwise until the opening and closing cycles.
Page 21
Maintenance and Modifications, cont’d (HSA 222 models only) Remove the four Phillips head Remove the pivot nut from the upper pivot bolt, then screws from the front access panel (figure 3-7). Retain the remove the bolt, releasing the upper end of the gas lift screws.
Maintenance and Modifications, cont’d Adjusting the Top Panel Level the top panel of the HSA 200 or HSA 222 as follows: If necessary to view the top and the underside of the enclosure simultaneously, remove the surface mount enclosure from the table. See “Removing and Replacing the Enclosure”, steps 1 through 4.
Maintenance and Modifications, cont’d HSA 200/222 Series Surface Access Products A ppendix A Reference Information Specifications HSA Part Numbers Included Parts Routing Templates Replacement Parts Accessories Top Plate Dimensions HSA 200/222 Series • Maintenance and Modifications 3-14...
ID bits are terminated on pins 4 and 11. Stereo channel separation >75 dB @ 20 Hz to 20 kHz Video input — HSA 200S, HSA 200C Audio input — HSA 200S, HSA 200C Number/signal type ..1 VGA–UXGA RGBHV, RGBS, RGsB, RsGsBs Number/signal type ..
Page 25
(11.84 cm W x 7.30 cm D) Storage: -40 to +158°F (-40 to +70°C) / 10% to HSA 200S, HSA 200SE, HSA 200C, HSA 200CE — USA models 90%, noncondensing Box (under surface) ..... 4.0" H x 4.6" W (front of unit) x 4.4" D Operating: +32 to +122°F (0 to +50°C) / 10% to...
0.25" (0.6 cm) User Access (Connectors and AAP Openings) TEMPLATE IS NOT FULL SIZE. Figure A-1 — HSA 200S/HSA 200SE/ HSA 222S cutout dimensions HSA 200/222 Series • Reference Information HSA 200/222 Series • Reference Information...
Reference Information, cont’d HSA 200C/HSA200CE/HSA222C US Models HSA 200/222 Series Surface Access Products 6.5" (16.5 cm) 6.000 0.0325" (15.24 0.083 cm) SURFACE CUT-OUT AREA = 6.000 0.0325" (15.24 0.083 cm) diameter Cut surface material out along this line. Tilting Plate A ppendix B Top Panel User Access (Connectors and AAP Openings)
Page 29
Packaging for Shipment The HSA 200’s and HSA 222’s ultra-fine machined surfaces and Disconnect all cables and remove the HSA 200 or HSA 222 moving parts make them vulnerable to damage caused by from the table or desk. See “Removing and Replacing the mishandling during shipment, if they are improperly packaged.
Page 30
Packaging for Shipment, cont’d Place the remaining foam shell on the other side of the HSA (figure B-4). Firmly push the foam shells together as far as they will go to completely suspend the HSA unit. Figure B-4 — HSA unit suspended in the foam Place the foam-protected HSA 200 or HSA 222 into the shipping carton (figure B-5).