Page 1
Automatic Blood Pressure Monitor Instruction manual page Mode d’emploi page Gebrauchsanweisung Seite Manuale di istruzioni pagina 89 Gebruiksaanwijzing pagina 45 Manual de instrucciones pagina 111 IM-HEM-637-E7-01-12/2011 5329374-8C...
Page 2
Automatic Blood Pressure Monitor Instruction manual page Mode d’emploi page Gebrauchsanweisung Seite Manuale di istruzioni pagina 89 Gebruiksaanwijzing pagina 45 Manual de instrucciones pagina 111 IM-HEM-637-E2-03-10/2010 5329374-8B...
Please take your time to read this instruction manual carefully before using it for the first time. If you still have questions please contact your OMRON dealer or the distributor as mentioned on the packaging. They will be pleased to help you.
English Before measuring your Blood Pressure Notes on Safety Please read thoroughly before using this monitor. • The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk of damage to you and others. •...
“Intellisense”. This is an advanced method of oscillometric measurement. No pre-setting of re- inflation is necessary. The OMRON R7 has a Position Sensor. The Position Sensor is able to determine the optimal height of your wrist (heart level) for the blood pressure measurement. Measuring at the heart level is extremely important since measuring at a higher or lower position will give wrong results.
English Main unit Batteries for monitoring Storage case (Two LR03 alkaline batteries) Instruction Manual Blood pressure pass Guarantee card Names and functions of the parts Main unit Wrist Cuff Battery Cover...
English Systolic Blood MEMORY RECALL Pressure Display button Push this button to Diastolic Blood see the measured Pressure Display values stored in the monitor. Date/Time Display Mark GRAPH CALL Displayed when a stored button measurement is shown. Push this button to see the graph.
(app. 2 months). How to set the Date and Time Before using your OMRON R7 for the first time, you have to set the date and time. After turning the monitor on by pushing the on/off button the initial screen (see picture) will be available for a few seconds.
Page 9
5) Pull the wrist cuff upward and close the cuff firmly with the Velcro tape as shown. You can use your OMRON R7 also on your right hand after selecting right wrist measurement in the SETTING MODE. People with a slender wrist (wrist circumference of less than 145mm) may feel loose because the cuff may not be wrapped firmly.
Position Sensor and the Signal will be ON and measuring at the left wrist will be pre set. Push the on/off button to activate your OMRON R7 and the Position Sensor Screen will be displayed.
English How to measure Blood Pressure Sustain your elbow with your other hand or a table to avoid movement. • Adjust the height of your wrist by using your elbow as a fulcrum. When the ( ) will reach the ( ) sign you will hear a beeping sound indicating that your blood pressure monitor is at the correct height (heart height).
) buttons you can enlarge the readings. How to use the Memory function Your OMRON R7 blood pressure monitor is able to store maximum 90 measurements including date and time. When your blood pressure monitor is holding 90 measurements the oldest will be deleted to store a new measurement.
English How to use the Graph function This monitor has the possibility to display the stored measurements as a graph. In order to get a clear history of your blood pressure the measurements are put in time zones: • Morning: Measurements made between 0:00 and 9:59 •...
210 mmHg. How to change the settings The settings of your OMRON R7 blood pressure monitor can be changed according to your own preferences and comfort. To enter the setting menu please press the SET button when your blood pressure monitor is switched off.
When the auto memory function is switched off the measurement will not be stored. When using your OMRON R7 monitor with more than one person it is recommended to disable the auto memory function. The auto memory function mode is ON when you purchased your OMRON R7 (factory preset).
English Position sensor The position sensor of your OMRON R7 can be switched ON or OFF. In the factory preset the position sensor is enabled. If the position sensor is switched ON you can choose to have the optimal wrist height supported by an acoustic sound (SIGNAL ON or OFF).
Delete data In this screen you are able to delete all stored measurement from you OMRON R7. Please be careful that deleted data cannot be restored. The factory preset is NO. If you choose YES the monitor will ask for a confirmation “ARE YOU SURE?”. To cancel select NO to confirm DELETE DATA select YES.
English What is Blood Pressure? Blood is pumped to artery by the beat Systolic blood pressure Diastolic blood pressure (contraction and expansion) of a pump called the heart. The pressure to pump Blood is pumped out. Blood returns to heart. out blood to artery is called the "systolic blood pressure."...
English Hypertension guide Systolic blood pressure (mmHg) The World Health Organization (WHO) and the International Society of Hypertension (ISH) Severe hypertension established the Blood Pressure Classification. Use this Classification as the guide to know the Moderate hypertension state of your blood pressure. However, if you Mild hypertension are concerned with your blood pressure, be Normal systolic value...
• Do not wash the cuff or make it wet. Please make sure no water will enter the main unit! • Keep your monitor in the storage case protected from extreme temperatures and humidity. • Do not carry out repairs of any kind yourself. If a defect occurs consult your OMRON dealer or distributor.
Battery replacement mark flashes. Trouble caused by Please contact the nearest OMRON dealer. abnormality in function. Only E and numerals are displayed. If you cannot resolve the problem even after taking the above-mentioned measures, please contact the nearest OMRON dealer.
Or the blood pressure deeply to relax yourself and make measurement again. values are displayed (Refer to Page 19.) abnormally high (low). If you cannot resolve the problem even after taking the above-mentioned measures, please contact the nearest OMRON dealer.
English Spare parts and accessories OMRON considers, due to the used high company and quality standards, the main unit as a non-serviceable part because of the necessity of proper calibration after replacement of high- tech components. The cuff can be replaced by an authorised expert.
Page 24
Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp THE NETHERLANDS www.omron-healthcare.com Production facility OMRON (DALIAN) CO., LTD. Dalian, CHINA Produktionsstätte Productiefaciliteit Site de production Oficina de producción...
Need help?
Do you have a question about the R7 and is the answer not in the manual?
Questions and answers