Honeywell F50F Product Data page 9

Duct mounted electronic air cleaner
Hide thumbs Also See for F50F:
Table of Contents

Advertisement

Mounting
The following mounting instructions assume that the W8600F
is mounted next to a T8600 Thermostat. If installing the
monitor at another location, modify the procedure to fit the
installation.
1. Hold the mounting template (included in the bag
assembly) next to the T8600 as shown in Fig. 9.
2. Mark the holes for the screw anchors and the
3-conductor thermostat cable.
3. Remove the template and drill the holes.
4. Remove the W8600F from the base.
THERMOSTAT
WALLPLATE
MOUNTING HOLES (2)
Fig. 9. Positioning mounting template.
5. Position the W8600F base over the holes and install
the anchors and screws. Tighten the screws until the
base is mounted firmly on the wall.
Select Wash Frequency
Use the W8600F DIP switches to program the time between
SERVICE indications. Be sure to select the setting according
to the conditions of the home. Factors to consider include the
duty cycle of the EAC, the number of people and pets, and
activities such as woodworking and other crafts that are being
done in the home.
Refer to Table 4 to select the wash frequency. Set the
W8600F DIP switches to match the selection. See Fig. 10.
The time listed represents actual run time of the EAC, not
calendar days.
Table 4. Wash Frequency Options.
DIP Switch Settings
F1
F2
F3
Off
Off
Off
Off
Off
On
Off
On
Off
Off
On
On
On
Off
Off
On
Off
On
On
On
Off
On
On
On
MOUNTING
TEMPLATE
WIRING HOLE
M11971
Wash Frequency
(Days)
10
20
30
40
50
70
100
180
F50F DUCT MOUNTED ELECTRONIC AIR CLEANER
BACK OF W8600F
1
3
Fig. 10. Back of W8600F.
Wiring
1. Run a 3-conductor thermostat cable (up to
18 gauge) from the W8600F to the terminal strip on
the air cleaner.
IMPORTANT
Connect cable to W8600F before attaching to the
air cleaner terminals to minimize the risk of
damage due to static electricity.
2. Connect the wires to terminals 1, 3 and 4 on the
W8600F. See Fig. 10.
3. Check that the battery is correctly installed in the
W8600F battery holder.
4. Snap the W8600F onto the base.
5. Turn off the power for the EAC.
WARNING
Electric Shock Hazard.
Can cause electrical shock or equipment
damage.
Disconnect EAC power and open the access door
before opening the power supply box cover.
6. Open the power supply box cover.
7. Remove the plug from the side of the power supply
box (plug can be a metal knockout or a blank terminal
strip).
8. Install the terminal block/cable assembly supplied with
W8600F kit.
9. Plug the connector on the end of the cable assembly
into the J2 terminal on the driver board (included with
W8600F kit). See Fig. 11.
9
BATTERY
IN HOLDER
DIP SWITCHES
WIRING
TERMINALS (3)
4
M11969
68-0137—5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents