DCS MO-24SS Technical Service Manual page 19

Microwave
Hide thumbs Also See for MO-24SS:
Table of Contents

Advertisement

PROCEDURE
LETTER
6. Re-install the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
G 1
K
RELAY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that these leads remain isolated from other components and oven chassis by using insulation
tape.
6. After that procedure, re-connect the power supply cord.
7. Remove the outer case and check voltage between Pin No. 1 of the 2 pin connector (A) and the
common terminal of the relay RY1 on the control unit with an A.C. voltmeter.
The meter should indicate 120 volts, if not check oven circuit.
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated ............. Defective relay.
DC. voltage not indicated ........ Check diode which is connected to the relay coil. If diode is good,
RELAY SYMBOL
8. Disconnect the power supply cord, and then remove outer case.
9. Open the door and block it open.
10. Discharge high voltage capacitor.
11. Reconnect all leads removed from components during testing.
12. Re-install the outer case (cabinet).
13. Reconnect the power supply cord after the outer case is installed.
14. Run the oven and check all functions.
COMPU DEFROST TEST
L
WARNING : The oven should be fully assembled before following procedure.
(1) Place one cup of water in the center of the turntable tray in the oven cavity.
(2) Close the door, touch the Defrost pad and touch the number pad 5 twice.
Then touch the start pad.
(3) The oven is in Compu Defrost cooking condition.
(4) The oven will operate as follows
(5) If improper operation is indicated, the control unit is probably defective and should be checked.
TEST PROCEDURES
G 2
G 3
G 4
G 5
MO24SS
control unit is defective.
OPERATIONAL VOLTAGE
RY1
Approx. 24.0V D.C.
RY2
Approx. 23.0V D.C.
1ST STAGE
WEIGHT
LEVEL
0.5lb
70%
COMPONENT TEST
G 6
G 7
G 8
Oven lamp / Turntable motor / Cooling fan motor
2ND STAGE
TIME
LEVEL
TIME
30sec.
40%
15sec.
17
G 9
G10
G11
G12
G13
G14
CONNECTED COMPONENTS
Power transformer

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for DCS MO-24SS

Table of Contents