Check code
Main
Outdoor 7-segment display
remote
controller
display
Auxiliary code
F01
F02
F03
F04
F04
F05
F05
F06
F06
F07
F07
F08
F08
F10
F12
F12
01: Comp. 1 side
F13
F13
02: Comp. 2 side
F15
F15
F16
F16
F23
F23
F24
F24
F29
F31
F31
01: Comp. 1 side
H01
H01
02: Comp. 2 side
01: Comp. 1 side
H02
H02
02: Comp. 2 side
01: Comp. 1 side
H03
H03
02: Comp. 2 side
H04
H04
H06
H06
H07
H07
01: TK1 sensor error
02: TK2 sensor error
H08
H08
03: TK3 sensor error
04: TK4 sensor error
H14
H14
01: TK1 oil circuit system error
02: TK2 oil circuit system error
H16
H16
03: TK3 oil circuit system error
04: TK4 oil circuit system error
L03
L04
L04
L05
L06
L06
No. of indoor units with priority
L07
L08
L08
L09
L10
L10
L20
L20
L28
L28
01: IPDU1 error
02: IPDU2 error
03: IPDU3 error
L29
L29
04: Fan IPDU error
05: IPDU1 + Fan IPDU error
06: IPDU2 + Fan IPDU error
07: All IPDU error
L30
L30
Detected indoor address
L31
Wireless remote controller
Sensor block display
AI-NET central
of receiving unit
control display
Timer Ready Flash
Operation
¤
¤
0F
¤
¤
0d
¤
¤
93
¤
¤
19
¤
¤
A1
¤
¤
18
¤
¤
18
¤
¤
1b
¤
¤
OC
¤
¤
A2
¤
¤
43
¤
¤
18
¤
¤
43
¤
¤
43
¤
¤
43
¤
¤
12
¤
¤
1C
¤
IF
¤
1d
¤
17
¤
44
¤
20
¤
d7
d4
¤
¤
44
¤
d7
¤
¤
96
¤
¤
96
¤
¤
96
¤
¤
96
¤
¤
99
¤
¤
99
¤
¤
46
¤
¤
88
¤
¤
98
¤
¤
46
¤
¤
CF
¤
¤
b6
20
Check code name
ALT
Indoor TCJ sensor error
ALT
Indoor TC2 sensor error
ALT
Indoor TC1 sensor error
ALT
TD1 sensor error
ALT
TD2 sensor error
ALT
TE1 sensor error
ALT
TL sensor error
ALT
TO sensor error
ALT
Indoor TA sensor error
ALT
TS1 sensor error
ALT
TH sensor error
ALT
Outdoor temp. sensor miscabling (TE, TL)
ALT
Outdoor pressure sensor miscabling (Pd, Ps)
ALT
Ps sensor error
ALT
Pd sensor error
SIM
Indoor other error
SIM
Indoor EEPROM error
Compressor break down
Magnet switch error
Overcurrent relay operation
Compressor trouble (lock)
Current detect circuit system error
Comp 1 case thermo operation
Low pressure protective operation
Oil level down detective protection
Oil level detective temp sensor error
Comp 2 case thermo operation
Oil level detective circuit error
Magnet switch error
Overcurrent relay operation
SIM
Indoor center unit duplicated
SIM
Outdoor line address duplicated
Duplicated indoor units with priority
SIM
(Displayed in indoor unit with priority)
Duplicated indoor units with priority
SIM
(Displayed in unit other than indoor unit with
priority)
SIM
Group line in individual indoor unit
SIM
Indoor group/Address unset
SIM
Indoor capacity unset
SIM
Outdoor capacity unset
SIM
Duplicated central control addresses
SIM
Over No. of connected outdoor units
SIM
No. of IPDU error
SIM
Indoor outside interlock
Extended I/C error
Judging device
Indoor
Indoor
Indoor
I/F
I/F
I/F
I/F
I/F
Indoor
I/F
IPDU
I/F
I/F
I/F
I/F
Indoor
I/F
IPDU
MG-SW
Overcurrent relay
IPDU
IPDU
I/F
I/F
I/F
I/F
I/F
I/F
MG-SW
Overcurrent relay
Indoor
I/F
I/F
I/F
Indoor
Indoor, I/F
Indoor
I/F
AI-NET, Indoor
I/F
I/F
Indoor
I/F