LG LS121HSV2 Submittal Data

High efficiency single zone inverter

Advertisement

Quick Links

Job Name/Location:
Date:
PO No.:
Architect:
Engr:
Rep:
(Company)
LS121HSV2
High Efficiency Single Zone Inverter
ODU - LSU121HSV2
IDU - LSN121HSV2
Performance:
Cooling:
Capacity (Btu/h)
SEER
EER
SEER - Seasonal Energy Efficiency Ratio EER - Energy Efficiency Ratio
Heating:
Capacity (Btu/h)
HSPF
HSPF - Heating Seasonal Performance Factor
Cooling Nominal Test Conditions:
Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Electrical:
Outdoor Unit:
Power Supply (V/Hz/Ø)
MOP (A)
MCA (A)
Cooling Rated Amps (A)
Heating Rated Amps (A)
Compressor (A)
Fan Motor (A)
MOP - Maximum Overcurrent Protection MCA - Minimum Circuit Ampacity
Indoor Unit:
Power Supply (V/Hz/Ø)
Cooling Power Input (kW)
Heating Power Input (kW)
Piping:
Liquid Line (in, OD)
Vapor Line (in, OD)
Additional Refrigerant (oz/ft)
Max Pipe Length (ft)¹
Piping Length (no add'l refrigerant, ft)
Max Elevation (ft)
Controls Features:
•24-Hour on/off  mer
•4-Way auto swing
•Auto changeover
•Auto restart
•Built-in low ambient standard, 
down to 14°F (cooling mode)
•Chaos wind
•Condensate Sensor Connec on
Optional Accessories (sold separately)
7-Day Programmable Controller (Black) - PQRCVSL0
7-Day Programmable Controller (White) - PQRCVSL0QW
Low Ambient Wind Baffle (Cooling operation to 0°F) - ZLABGP01A
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com
For:
GC:
Mech:
(Project Manager)
11,200
20.0
12.5
13,300
11.0
Heating Nominal Test Conditions:
Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
208-230/60/1
10.0
7.3
8.1
7.6
0.25
208-230/60/1
0.90
1.0
1/4
3/8
0.22
•Energy saving
•Inverter (variable speed 
compressor)
•Jet cool/Jet heat
•Plasma air purifying system
•Self-cleaning indoor coil
•Sleep mode
•Ultra quiet opera on
File
Resubmit
Approval
Other
Operating Range:
Outdoor Unit:
Cooling (°F DB)
Heating (°F WB)
Indoor Unit:
Cooling (°F DB)
Heating (°F DB)
Unit Data:
Refrigerant Type
Refrigerant Control
Refrigerant Charge (lbs)
ODU Sound Pressure (±3 dB(A))²
IDU Sound Pressure (±3 dB(A))²
ODU Net Unit Weight (lbs)
15
ODU Shipping Weight (lbs)
IDU Net Unit Weight
IDU Shipping Weight (lbs)
Heat Exchanger Coating
Communication Cable (No x AWG)³
Fan:
ODU Type
IDU Type
Fan Speeds (Fan/Cooling/Heating)
Quantity (ODU + IDU)
Motor/Drive
ODU Max Air Flow Rate (CFM)
IDU Max Air Flow H/M/L (CFM)
Dehumidification (pts/hr)
Notes:
1.Piping lengths are equivalent.
65
2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
3.All communica on cable to be minimum 18 AWG, 2-conductor, stranded, shielded and 
41
must comply with applicable local and national code.
4.See Engineering Manual for sensible and latent capaci es.
32
5.Power wiring cable size must comply with the applicable local and na onal code.
6.The indoor unit comes with a dry helium charge.
7.This data is rated 0   above sea level, with 24.6   of refrigerant line and a 0   level 
difference between outdoor and indoor units.  
8.Must follow installa on instruc ons in the applicable LG installa on manual.
Standard Features:
•Limited Five Year Compressor Warranty
•Limited Two Year Func onal Parts Warranty
Tag #:
Brushless Digitally Controlled/Direct
DFS-SB-AA-022-US 012F26
14-118
5-75
64-86
60-86
R410A
EEV
2.21
45
39/33/24
77.2
81.6
22.1
26.5
GoldFin™
4 x 18
Propeller
Cross Flow
6/Auto/Chaos
1 + 1
1,165
350/280/210
3.0
Page 1 of 2

Advertisement

loading

Summary of Contents for LG LS121HSV2

  • Page 1 Max Pipe Length (ft)¹ 2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 3.All communica on cable to be minimum 18 AWG, 2-conductor, stranded, shielded and  Piping Length (no add'l refrigerant, ft) must comply with applicable local and national code. 4.See Engineering Manual for sensible and latent capaci es. Max Elevation (ft) 5.Power wiring cable size must comply with the applicable local and na onal code. 6.The indoor unit comes with a dry helium charge. Controls Features: 7.This data is rated 0   above sea level, with 24.6   of refrigerant line and a 0   level  difference between outdoor and indoor units.   •24-Hour on/off  mer •Energy saving 8.Must follow installa on instruc ons in the applicable LG installa on manual. •4-Way auto swing •Inverter (variable speed  Standard Features: •Auto changeover compressor) •Limited Five Year Compressor Warranty •Auto restart •Jet cool/Jet heat •Limited Two Year Func onal Parts Warranty •Built-in low ambient standard,  •Plasma air purifying system down to 14°F (cooling mode) •Self-cleaning indoor coil •Chaos wind •Sleep mode...
  • Page 2 Job Name/Location: ODU - LSU121HSV2 Tag #: Date: High Efficiency Single Zone Inverter PO No.: For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com DFS-SB-AA-022-US 012F26 Page 2 of 2...
  • Page 3 Job Name/Location: Tag #: IDU ‐ LSN121HSV2 Date: High Efficiency Single Zone Inverter PO No.: For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com DFS‐SB‐AA‐022‐US 012F26 Page 3 of 3...