Piping Diagrams - LG AUUW243D Manual

Exploded view
Hide thumbs Also See for AUUW243D:
Table of Contents

Advertisement

3. Piping Diagrams

Refrigerant Flow
Cooling
Heating
Gas
(Ø 15.88mm)
Field Piping
Liquid
(Ø 9.52mm)
LOC.
EEV
Electronic Expansion Valve
Th1
Thermistor for suction pipe temperature
Th2
Thermistor for discharge pipe temperature
Th3
Thermistor for condenser pipe temperature
Th4
Thermistor for outdoor air temperature
Th5
Thermistor for condenser middle pipe temperature
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Accumulator
r
E.E.V.
Description
- 4 -
Reversing
Valve
High Pressure
S/W
Th2
Th1
Inverter
Compressor
PCB Connector
CN_LEV1
CN_TH3
CN_TH3
CN_TH2
CN_TH2
CN_TH4
OUTDOOR UNIT
Th4
Heat
Exchanger
Th5
Th3
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Luu245hv

Table of Contents