Stacking Condenser Unit - Hoshizaki KM-1900SAH/3 Instruction Manual

Stackable crescent cuber
Hide thumbs Also See for KM-1900SAH/3:
Table of Contents

Advertisement

1) Remove the louver panel. See Fig. 15.
2) Remove the junction box cover on the remote condenser unit. Remove the fan motor
junction box cover on the icemaker.
3) Install a ground wire from the icemaker to the remote condenser unit. Use wire of an
appropriate gage and outdoor rating.
4) Install line and neutral wires from the fan motor leads in the icemaker to the leads in
the remote condenser unit junction box. Use wire of an appropriate gage and outdoor
rating.
5) Replace the junction box covers and the louver panel in their correct positions.
Remote Condenser Unit
Louver Panel

7. Stacking Condenser Unit

1) Install the lower remote condenser unit as described earlier in this section.
2) Place the upper remote condenser unit on top of the lower. See Fig. 16.
3) Secure the upper remote condenser unit to the lower remote condenser unit with the
4 screws provided.
4) Install refrigerant lines and make electrical connection as described earlier in this
section.
Junction Box
Cover
Screws
Fig. 15
Screws
Fan Motor Junction
Box Cover
Screw
Upper Remote
Condenser Unit
Screws
Lower Remote
Condenser Unit
Fig. 16
26
Icemaker

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-1900srh3Km-1900swh3Km-1900sahKm-1900swhKm-1900srh

Table of Contents