Location; Setup - Hoshizaki KM-1900SAH/3 Instruction Manual

Stackable crescent cuber
Hide thumbs Also See for KM-1900SAH/3:
Table of Contents

Advertisement

C. Location
1. This icemaker is not intended for outdoor use. Normal operating ambient
temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating
water temperature should be within 45°F to 90°F (7°C to 32°C). Operation
of the icemaker, for extended periods, outside of these normal temperature
ranges may affect icemaker performance.
2. This icemaker will not work at sub-freezing temperatures. To prevent damage
to the water supply line, drain the icemaker if the air temperature is going to
go below 32°F (0°C). See "III.C. Preparing the Icemaker for Long Storage."
For best operating results:
• Icemaker should not be located next to ovens, grills, or other high heat producing
equipment.
• Location should provide a firm, level foundation for the equipment.
• Allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of
maintenance and/or service should they be required.
D. Setup
Before operating the icemaker, the bin control thermostat assembly must be
installed correctly. Failure to properly install the assembly could result in ice
backup and unit damage.
1) Unpack the storage bin, then attach the 4 adjustable legs provided (bin accessory) to
the bottom of the storage bin.
2) Position the storage bin in the selected permanent location.
3) Place the icemaker on top of the storage bin.
4) Secure the icemaker to the storage bin
using the 2 mounting brackets and the
bolts provided. See Fig. 2.
5) Level the icemaker/storage bin in both the
left-to-right and front-to-rear directions.
Adjust the storage bin legs to make the
icemaker level.
CAUTION
CAUTION
15
Icemaker
Bolts
Mounting
Brackets
Bin
Fig. 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-1900srh3Km-1900swh3Km-1900sahKm-1900swhKm-1900srh

Table of Contents