a) Default Dip Switch Settings

Note that the settings vary for KM-1601SRH/3 depending on the water valve installed.
The dip switches are factory set to the following positions:
Auxiliary
Model
Code
KM-1601SAH/3
Dip switch settings for air-cooled units
"G" Control Board
are as listed, regardless of auxiliary
code.
KM-1601SWH/3
Dip switch settings for water-cooled
"E" Control Board
units are as listed, regardless of
auxiliary code.
KM-1601SRH/3
R-0, R-1,
"E" Control Board
some S-1
Some S-1
S-2 & later
V-1 (M) & later 4A5251-04 (11 l/min)
S5 Dip Switch (Do Not Adjust)
Model
1
KM-1601SAH/3
OFF OFF OFF OFF OFF
KM-1601SWH/3
KM-1601SRH/3
S4 Dip Switch
All Models
Freeze Timer (9 & 10)
Factory Use (8)
Harvest Pump Timer (7) KM-1601SAH/3 "G" Control Board
Bin Control Selector (7) KM-1601SWH/3 & KM-1601SRH/3
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Water
Valve Part
Number
3U0111-02
(8 l/min)
3U0111-01
(15 l/min)
4A1176-04 (11 l/min)
S5 Dip Switch No.
2
3
4
5
Not Applicable
"E" Control Board
CAUTION
S4 Dip Switch
Code on
Water
1
2
3
Valve
OFF OFF ON ON ON ON ON OFF OFF OFF
OFF OFF OFF OFF ON ON OFF OFF OFF ON
J248-032
ON OFF ON OFF OFF OFF OFF OFF OFF OFF
J248-030
ON OFF OFF OFF ON ON OFF OFF OFF OFF
KM-1601SAH/3 "G" Control Board
32
S4 Dip Switch No.
4
5
6
7
8
S5 Dip Switch
Refill Counter (2 through 5)
Float Switch Selector (1)
9
10