CHAPTER 5 - TESTING CLIMBMAX PERFORMANCE
You can test the electronics inside ClimbMax by using test mode. In test mode, you can adjust the
tension of the drive belt, check the odometer reading, and test all the LEDs on the console.
To enter test mode, turn the ClimbMax off, then press and hold the HR Control key while turning
it back on. All displays will light until you release the key.
In test mode, the red lights above and below the Progress Indicator fields show the state of the
ClimbMax's various input/output signals:
Indicator
Elapsed Time
Calories
Speed
Heart Rate/Level
Distance
Calories/Hour
The Elapsed Time field shows "CL1," indicating this is a ClimbMax 1000; Calories shows the
version number of the ClimbMax's internal software; Speed shows the state of the slack switch
(either "On" or "Off").
While the climber is in test mode, some of the console keys have special functions:
Switch Display
Up Arrow
Down Arrow
Endurance
Strength
Manual or
HR Control
Enter or
Fat Burning
Clear
Signal
Not used
Slack Switch
RPM sensor off
Polar signal
Not used
Not used
Displays the odometer reading and RPM sensor data.
Press HR Control to return to the normal test mode
display.
Loosens the belt. The belt tensioning motor runs for as
long as you hold the key down. Don't loosen the belt
for too long, or you may tangle or unsnap the belt.
Tightens the belt. The belt tensioning motor runs for as
long as you hold the key down.
Tests each LED digit group, in turn. Press the key
again to go to the next group. Press Clear to return to
the normal test mode display.
Tests each LED segment, in turn. Press the key again
to go the next segment. Press HR Control to return to
the normal test mode display.
Clears special displays and returns to normal test mode
display.
Lights all display LEDs. Press HR Control to return
to the normal test mode display.
From normal display, ends test mode.
Normal
off
on
-
off
off
off
Need help?