CONTROL PWB SECTION
CONTROL PWB SECTION
This Section of the Presentation will cover troubleshooting the Control Board Assembly. Upon completion
of this section the Technician will have a better understanding of the circuit and be able to locate voltage
and resistance test points needed for troubleshooting.
Signals
Signals
Operating Voltages
Operating Voltages
Y
SUS
Supplied
Y
SUS
Supplied
•
DC Voltage and Waveform Test Points
•
Resistance Test Points
Main Board Supplied
Y SUS Supplied
Developed on the
Control board
15V supplied to Control board from the Y-SUS board.
But routed through Control board to Z-SUS.
15V not used by the Control board.
LVDS Signal
5V VCC
1.8V
(2) 3.3V
Plasma Spring 2009