Safety & Handling Regulations
1. Approximately 10 minute pre-run time is required before any adjustments are performed.
2. Refer to the Voltage Sticker inside the Panel when making adjustments on the Power Supply, Y SUS and Z SUS Boards.
Always adjust to the specified voltage level (+/- ½ volt). Unless otherwise noted.
3. Be cautious of electric shock from the PDP module since the PDP module uses high voltage, check that the Power Supply
and Drive Circuits are completely discharged because of residual current stored before Circuit Board removal.
4.
C-MOS circuits are used extensively for processing the Drive Signals and should be protected from static electricity.
5.
The PDP Module must be carried by two people.
6.
Also the Plasma television MUST be transported vertical NOT horizontal.
7.
Exercise care when making voltage and waveform checks to prevent costly short circuits from damaging the unit.
8.
Be cautious of lost screws and other metal objects to prevent a possible short in the circuitry.
Checking Points to be Considered
1. Check the appearance of the Replacement Panel and Circuit Boards for both physical damage and part number accuracy.
2. Check the model label. Verify model names and board model matches.
3. Check details of defective condition and history. Example: Y Board Failure, Mal-discharge on screen, etc.
Always carry vertical NOT horizontal.