Diagnostic Error Code
071-00X-XXX 071-01X-XXX 071-02X-XXXAudio port
error
071-03X-XXX Audio port failure
071-04X-XXX Audio port failure
071-195-XXX Audio port Test aborted by user
071-196-XXX Audio port test halt, error threshold
exceeded
071-197-XXX Audio port test warning
071-198-XXX Audio port test aborted
071-199-XXX Audio port test failed, cause unknown
071-25X-XXX Audio port failure
080-000-XXX Game Port interface Test Passed
080-XXX-XXX Game Port interface Error
080-195-XXX Game Port interface Test aborted by user
080-196-XXX Game Port interface test halt, error
threshold exceeded
54
ThinkCentre Hardware Maintenance Manual
FRU/Action
1. Run the Setup Utility program.
2. Flash the system. See "Updating (flashing) BIOS
from a disc" on page 208.
3. System board
1. Speakers
2. Microphone
3. Audio card, if installed
4. System board
1. Run the Setup Utility program.
2. Audio card, if installed
3. System board
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using the
Setup Utility" on page 39.
2. Re-run the test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using the
Setup Utility" on page 39.
2. Flash the system and re-test. See "Updating
(flashing) BIOS from a disc" on page 208.
3. Go to "Undetermined problems" on page 62.
1. See "Undetermined problems" on page 62.
2. Flash the system and re-test. See "Updating
(flashing) BIOS from a disc" on page 208.
3. Replace component under function test.
1. Speakers
2. Audio card, if installed
3. System board
No action
1. Remove the game port device and re-test the system.
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.