Executing Iop Measurement - Sony DVP-NS355 Service Manual

Cd/dvd player with remote control rmt-d165a/rmt-d165p/rmt-d166p
Hide thumbs Also See for DVP-NS355:
Table of Contents

Advertisement

6-5. EXECUTING IOP MEASUREMENT

In order to execute mirror time adjustment, the following standard
procedures must be followed.
(1)
In standby mode, press
[POWER]
to enter Remocon Diagnosis Mode.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
5. Video Level Adjustment
Model
: DPX-1790_UC2
IF-con Ver
: 1.000 (5B84)
Syscon Ver : 1.81
Select "2. Drive Manual Operation" by pressing the 2
(2)
key on the remote commander. The screen will appear as
below.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to top Menu
(3)
Select "3. Manual Adjustment" by pressing the 3 key on
the remote commander. The screen will appear as below.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
? ? Change Value
[RETURN] Return to previous menu
(4)
Select Iop by pressing 6 key on the remote commander.
[TOP MENU]
[CLEAR]
,
,
(5)
Wait until a hexadecimal number appear.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
Change Value
[0] Return to previous menu
(6)
Convert data from hexadecimal to decimal using conver-
sion table.
(9)
Press [RETURN] to return back to previous menu.
(10)
Press 0 to return to Top Menu and power OFF the DVD
Player.
6-3

Hide quick links: